HEATING
1
Heating Speed Dip
Switch Setting
First Stage heating Speed - cfm
Second Stage Heating Speed-cfm
+24%
1425
1920
+18%
1355
1830
+12%
1290
1735
+6%
1220
1645
Fauctory Default
1150
1550
-6%
1080
1460
-12%
1010
1365
-18%
945
1270
COOLING
1
Cooling Speed DIP
Switch Settings
First Stage Cooling Speed -cfm
Second Stage Cooling Speed-cfm
Low Medium-Low
Medium-High
2
High
Low
Medium-Low
Medium-High
2
High
+
935
1073
1240
1405
1320
1540
1760
2010
Factory
850
975
1125
1275
1200
1400
1600
1825
-
765
880
1015
1150
1080
1260
1440
1640
A96US2V090C20S BLOWER PERFORMANCE (less filter)
0 through 0.8 in. w.c. (Heating) and 0 through 1.0 in. w.c. (Cooling) External Static Pressure Range
HEATING
1
Heating Speed Dip
Switch Setting
First Stage heating Speed - cfm
Second Stage Heating Speed-cfm
+24%
1520
1610
+18%
1445
1535
+12%
1370
1455
+6%
1300
1380
Fauctory Default
1225
1300
-6%
1150
1225
-12%
1080
1145
-18%
1005
1065
COOLING
1
Cooling Speed DIP
Switch Settings
First Stage Cooling Speed -cfm
Second Stage Cooling Speed-cfm
Low Medium-Low
Medium-High
2
High
Low
Medium-Low
Medium-High
2
High
+
770
935
1075
1235
1100
1320
1540
1760
Factory
700
850
975
1125
1000
1200
1400
1600
-
630
765
880
1015
900
1080
1260
1440
A96US2V110C16S BLOWER PERFORMANCE (less filter)
0 through 0.8 in. w.c. (Heating) and 0 through 1.0 in. w.c. (Cooling) External Static Pressure Range
1
Cooling and Heating speed are based on a combination of DIP switch setting on the furnace control. Refer to installation instructon for specific DIP
Switch settings
2
Factory default setting
NOTES:
The effect of static pressure is included in air volumes shown.
First stage Cool (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position
Continous Fan Only speed approximately 50% of the selected second stage cooling speed - minimum 500cfm.
1
Cooling and Heating speed are based on a combination of DIP switch setting on the furnace control. Refer to installation instructon for specific DIP
Switch settings
2
Factory default setting
NOTES:
The effect of static pressure is included in air volumes shown.
First stage Cool (two stage air conditioning units only) is approximately 70% of the same second stage COOL speed position
Continous Fan Only speed approximately 50% of the selected second stage cooling speed - minimum 500cfm.
Содержание A96US2V
Страница 3: ...507404 02 Page 3 of 80 Issue 1448 EXPANDED VIEW Figure 1 ...
Страница 31: ...507404 02 Page 31 of 80 Issue 1448 Figure 38 ...
Страница 38: ...507404 02 Page 38 of 80 Issue 1448 Figure 56 TRAP DRAIN ASSEMBLY USING 1 2 PVC or 3 4 PVC ...
Страница 41: ...507404 02 Page 41 of 80 Issue 1448 Table 9 ...
Страница 45: ...507404 02 Page 45 of 80 Issue 1448 ...
Страница 47: ...507404 02 Page 47 of 80 Issue 1448 Integrated Control Figure 56 ...
Страница 78: ...507404 02 Page 78 of 80 Issue 1448 Start Up Performance Check List UNIT SET UP ...
Страница 79: ...507404 02 Page 79 of 80 Issue 1448 UNIT OPERATION Heating Mode Cooling Mode ...