© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Adjustments
70458101 (EN)
70
IMPORTANT: Airflow switch vane must remain
closed during operation. If it opens and closes
during the drying cycle, this indicates insufficient
airflow through the tumble dryer. If switch remains
open, or pops open and closed during the cycle, the
heating system will shut off. The cylinder and fan
will continue to operate even though the airflow
switch is indicating insufficient airflow.
NOTE: To properly mount the airflow switch
bracket, or in case of a load not drying, the airflow
switch bracket may need to be checked for proper
alignment. Be sure the locator pins are securely in
their respective holes before tightening the bracket
mounting screws. This will assure proper
alignment of the airflow switch arm in the channel
of the airflow switch bracket and prevent binding
of the arm.
Loading Door Switch
Loading door switch is factory preset, no field
adjustment is necessary.
Loading Door Catch (120 and 170
Series Models)
The door catch must be adjusted to have sufficient
tension to hold loading door closed against force of load
tumbling against it. Proper adjustment is when
0.48-1.03 bar (7-15 pounds) pull is required to open
door.
If adjustment is required, refer to
Figure 39
and
proceed as follows:
To adjust, open door, loosen acorn nut and turn door
strike screw in or out as required. Tighten acorn nut.
Figure 39
WARNING
The tumble dryer must not be operated if
the airflow switch does not operate
properly. Faulty airflow switch operation
may cause an explosive gas mixture to
collect in the tumble dryer.
W072R1
T048I
1
Door Latch
2
Door Catch
3
Acorn Nut
2
3
1