Gas Requirements
IMPORTANT: Any product revisions or conversions
must be made by the Manufacturer’s Authorized
Dealers, Distributors or local service personnel.
IMPORTANT: The tumble dryer must be isolated
from the gas supply piping system by closing its
individual manual shut-off valve during any
pressure testing of the gas supply piping system at
test pressure equal to or less than 3.45 kPa,
34.5 mbar (0.5 psig).
NOTE: For gas valves with a manual shut-off
switch on the gas valve, the shut-off switch does not
protect the valve from this pressure test. Use the
individual manual shut-off valve from the gas
supply piping system to protect the gas valve.
IMPORTANT: The tumble dryer and its manually
operated appliance gas valve must be disconnected
from the gas supply piping system during any
pressure testing of that system at test pressures in
excess of 3.45 kPa, 34.5 mbar (0.5 psig).
IMPORTANT: The installation must comply with
local codes or, in the absence of local codes:
with the latest edition of the “National Fuel
Gas Code,” ANSI Z223.1/NFPA 54 in the
U.S.A.
with CAN/CSA-B149.1 Natural Gas and
Propane Installation Code in Canada
and Gas Installations Standard AS/NZS 5601
Part 1: General Installations in Australia and
New Zealand
Obtain specific gas service pipe size from the gas
supplier. Refer to
Table 7
for general pipe size.
The following must be furnished and installed by the
customer for the gas service line to each tumble dryer.
Refer to
Figure 15
.
Sediment traps
Shut-off valves
Supply pressure taps
It is important that equal pressure be maintained at all
tumble dryer gas connections. This can be done by
installing a 25.4 mm (1 inch) pipe gas loop to maintain
equal pressure at all gas connections. Refer to
Figure 16
.
NATURAL GAS pressures with all gas appliances
running (tumble dryers, water heaters, space heaters,
furnace, etc.):
Maximum gas pressure – 26.1 mbar (10.5 water
column inches)
Recommended gas pressure – 16.2 mbar (6.5 water
column inches)
Minimum gas pressure – 12.4 mbar (5 water
column inches)
WARNING
To reduce the risk of fire or explosion, DO
NOT CONNECT THE GAS LINE TO THE
TUMBLE DRYER IF THE GAS SERVICE IS
NOT THE SAME AS THAT SPECIFIED ON
THE TUMBLE DRYER SERIAL PLATE! It
will first be necessary to convert the gas
burner orifice and gas valve. Appropriate
conversion kits are available.
W060R1
To reduce the risk of gas leaks, fire or
explosion, use a new flexible stainless
steel connector.
W774
WARNING
To reduce the risk of fire or explosion, if
the tumble dryer is to be connected to
Liquefied Petroleum (L.P.) gas, a vent to
the outdoors must be provided in the
room where the tumble dryer is installed.