background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9

201956

Grounding Information

The washer must be grounded. In the event of 

malfunction or breakdown, grounding will reduce the 

risk of electric shock by providing a path of least 

resistance for electric current.
The washer is equipped with a cord having an 

equipment-grounding conductor and a 3-prong 

grounding plug. The plug must be plugged into an 

appropriate outlet that is properly installed and 

grounded in accordance with all local codes and 

ordinances.

Do not modify the plug provided with the washer - if it 

will not fit the outlet, have a proper outlet installed by 

a qualified electrician.

NOTE: Have a qualified electrician check the 
polarity of the wall receptacle. If a voltage reading 
is measured other than that in 

Figure 13

, the 

qualified electrician should correct the problem.

NOTE: The wiring diagram is located in the 
control hood.

Step 7: Add Water to the Washer

To prevent damage to pump, do not run washer before 

adding at least one quart water to the tub. If the washer 

is run before any water is added, the pump seal may 

overheat causing the pump to leak. Once installed, the 

water retained in the drain system from the previous 

cycle will provide sufficient cooling to prevent pump 

seal damage.

NOTE: The agitator should not be removed except 
for service. The washtub is designed to be self-
cleaning.

Improper connection of the equipment-
grounding conductor can result in a risk 
of electric shock. Check with a qualified 
electrician or service person if you are in 
doubt as to whether the washer is 
properly grounded.

W216

WARNING

This unit is equipped with a three-prong 
(grounding) plug for your protection 
against shock hazard and should be 
plugged directly into a properly grounded 
three-prong receptacle. Do not cut or 
remove the grounding prong from this 
plug.

W213

WARNING

W391I

Figure 14 

W391I

Содержание Topload washer

Страница 1: ...e changes ownership this manual must accompany machine www comlaundry com Installation Instructions for Topload Washers Washer Dimensions 2 Before You Start 2 Installation 3 Installer Checklist Back C...

Страница 2: ...on Installation Instructions User s Guide Warranty Bond NOTE If the washer is delivered on a cold day below freezing or is stored in an unheated room or area during the cold months do not attempt to o...

Страница 3: ...o front or sides when moving Save the shipping brace and plug They must be reinstalled whenever washer is moved or transported to a new location This will prevent damage to the washer Refer to the Use...

Страница 4: ...nd of the fill hoses as shown in Figure 5 The screen must be facing outward Screw hose couplings with the filter screens onto the water faucets until they are finger tight Then using a pliers screw ap...

Страница 5: ...ctions below IMPORTANT Drain receptacle must be capable of handling a minimum of 3 2 cm 1 1 4 inch outside diameter drain hose Standpipe Installation Place the adapter into the standpipe The recommend...

Страница 6: ...using the beaded strap from accessories bag Refer to Figure 9 NOTE End of drain hose must be below height of cabinet top Laundry Tub Installation For this type of installation the drain hose MUST be s...

Страница 7: ...level tilt washer back to access the front leveling legs Loosen the locknuts and adjust legs by screwing into or out of washer base Once adjusted tilt the washer forward on front legs and lower back...

Страница 8: ...d directly into a polarized three slot effectively grounded receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 13 to determine correct polarity of the wall receptacle DRY202...

Страница 9: ...ect the problem NOTE The wiring diagram is located in the control hood Step 7 Add Water to the Washer To prevent damage to pump do not run washer before adding at least one quart water to the tub If t...

Страница 10: ...tch Washer should stop agitating and spinning when lid is opened Step 9 Check Installation Refer to Installer Checklist on the back cover of this manual and make sure that washer is installed correctl...

Страница 11: ...ions d installation de machines laver chargement par le dessus Dimensions de la machine laver 12 Avant de commencer 12 Installation 13 V rfication de l installation Couverture arri re Date de l achat...

Страница 12: ...tallation Guide de l utilisateur Bon de garantie REMARQUE Si la machine laver est livr e un jour o il fait froid temp rature en dessous de z ro ou qu elle est entrepos e dans une pi ce non chauff e du...

Страница 13: ...ie et le bouchon d exp dition Ils devront tre r install s si la machine laver est d plac e ou transport e ailleurs Ils emp chent l endommagement de la machine Consulter le guide de l utilisateur pour...

Страница 14: ...res Les placer dans chaque extr mit des tuyaux de remplissage comme illustr dans Figure 5 Le filtre doit tre tourn vers l ext rieur Serrer la main les raccords de tuyau dot s de filtres sur les robine...

Страница 15: ...3 2 cm 1 1 4 po minimum Installation de la colonne montante Placer l adaptateur dans la colonne montante La conduite verticale doit faire 91 44 cm 36 po de hauteur Nous d conseillons d installer des c...

Страница 16: ...Se reporter au Figure 9 REMARQUE L extr mit du tuyau de vidange ne doit pas se trouver sous la partie sup rieure de la machine Installation au bac laver Pour ce type d installation le tuyau de vidange...

Страница 17: ...e n est pas le cas la pencher vers l arri re pour acc der aux pieds avant ajustables Desserrer les contre crous et r gler les pieds en les vissant ou en les d vissant du socle de la machine laver Une...

Страница 18: ...lectriques en fournissant un chemin de moindre r sistance au courant lectrique La machine est quip e d un c ble dot d un conducteur de mise la masse pour quipement et d une fiche de mise la masse troi...

Страница 19: ...de surchauffer entra nant ensuite des fuites Une fois install e l eau restant dans le syst me de vidange du cycle pr c dent permettra un refroidissement suffisant qui emp chera d endommager la pompe R...

Страница 20: ...reens Filtres Hot Valve Connection Raccord de robinet d eau chaude Plain Washers Machines laver normales Red Rouge Blue Bleu TLW1988N Connect Fill Hoses Connecter les tuyaux de remplissage Cold Valve...

Отзывы: