23. WASHER WILL NOT FILL
Washer Will Not Fill.
Is there 120 Volt
AC across the input side of
the pressure switch to "FS2" on
the motor control board?
Correct wiring
between pressure
switch and control
board.
No
Is there 120 Volt
AC from the input side of the
mixing valves to "FS2" on the
motor control board?
Yes
(1)
(2)
(3)
Yes
Check for cracked
or broken wiring
at the pressure
switch. Change
inoperative
pressure switch.
Is there 120 Volt
AC from the input side of
the mixing valve to "H1-9" or "H1-3"
of the motor control board?
Yes
No
No
Change the motor
control board.
Change the mixing
valve.