30
800168
Section 3 Troubleshooting (EDC Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
12. WASHER OVERFLOWS
Washer overflows
Correct wiring between
pressure switch and
mixing valve.
Disconnect power to
washer.
Change inoperative
pressure switch.
Note:
Go through the following tests if water is
at least half way up the door glass.
Yes
Yes
(1) "AC"
(2) "AC"
Yes
No
Washer still fills.
No
Is there voltage on
terminal 24 on
pressure switch to
"FS-2" on motor
control?
Properly attach
pressure hose or
replace hose if cut.
No
Is there voltage at
mixing valve to
"FS-2" on motor
control?
Change inoperative
mixing valve.
Is Pressure Bulb Hose
properly attached and
free of cuts?
H140SE3B
Содержание SWF561*E
Страница 2: ......
Страница 44: ...42 800168 Section 3 Troubleshooting EDC Models Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT ...
Страница 47: ...800168 45 Section 3 Troubleshooting MDC Models Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT ...
Страница 62: ...60 800168 Section 3 Troubleshooting MDC Models Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT ...
Страница 84: ...82 800168 Section 4 Grounding Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT ...