Section 3 Troubleshooting (EDC Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
7. COINS IGNORED WHEN ENTERED
Start Coin drop Diagnostic test.
Enter
several
coins
Open
control panel
Check coin drop
Make sure control is
reset properly and
prompting for a vend.
No
Yes
Yes
No
Yes
Yes
Does the display
coin counter
increment properly?
Is
connection at
"H2" (models with the
letter "E" in the 8th character
of the model number) or "H7"
(models with the letter "H" in the
8th character of the model
number) firmly seated
in its receptacle
on control?
Is 3-pin
connector plug
firmly seated in its
receptacle on
coin drop?
Are wires
exiting coin drop
optical sensor
cracked or broken?
Reconnect
and test
again.
No
No
Reconnect
and test
again.
Replace coin
drop.
Retest again, if not successful the
following is the problem:
- Replace coin drop.
If problem still exists:
- Replace electronic control.
H131SE3B