Page 15
Alliance Appliances Pty Ltd
Rapid 26
3. Australian Consumer Law
3.1 Our goods come with guarantees that cannot be excluded under Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and for compensation for
any other unforeseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of an acceptable quality and failure does not amount to a
major failure.
3.2 This Alliance warranty is in addition to any rights and remedies that you may have under
the
Australian Consumer law.
GENERAL INSTALLATION REQUIREMENTS
• This heater must be installed in accordance with
> Current issues of AS/NZS 3000, AS/NZS 3500.4 and AS/NZS 5601 and
> These installation instructions and
> All local codes and regulatory authority requirements
• This heater must be installed, serviced or removed only by an Authorised Person
• Alliance continuous flow gas water heaters are designed for “Outdoor” installation only.
• The heater must only be connected to the gas type marked on the heater.
• The gas meter, regulator and supply pipes must be sufficiently large to deliver the rated
gas input for all gas appliances that are planned to be installed at the premises. The Gas
Installation Standard AS/NZS 5601 sets out the method of determining pipe sizing to the
water heater.
• The heater is designed for connection to mains water supply pressure. To achieve the
rated flow and performance the supply pressure must be within the range of 200kPa to
1000kPa.
> If the water supply pressure exceeds 1000 kPa it must be reduced with an approved
pressure limiting valve.
> The heater should not be connected to a household gravity water supply.
• For continued and reliable operation the heater must only be connected to water supplies
with suitable chemical properties and cleanliness.
The warranty section of these instructions outlines the limits on the water chemistry and
cleanliness.
Most metropolitan water supplies are suitable but you should contact your water supply
authority to confirm that your water is within the limits set out in the warranty.
• An approved and suitably positioned standard 240V AC 10amp outdoor earthed power
point is required. Waterproof model if required. The electrical supply lead on the heater is
1.8m long.
• THIS HEATER MUST NOT BE INSTALLED TO HEAT EITHER A DOMESTIC SPA OR
SWIMMING POOL