Страница 3: ...d Rapid 26 MODELS COVERED THIS WATER HEATER MUST BE INSTALLED AND SERVICED BY AN AUTHORISED PERSON On completion of installation please give these Instructions to the householder Natural Gas RAPID R26...

Страница 4: ...ecord the following information below for your own records Model No REU Serial No Your Retailer Address Contact Number Purchase Date Your Installer Address Installers License No Contact Number Install...

Страница 5: ...d person will have insurance protecting their workmanship for 6 years Make sure you use a licensed person to install this water heater and ask for your Compliance Certificate Installing Plumber Upon c...

Страница 6: ......

Страница 7: ...PROTECTION 8 IMPORTANT INFORMATION FOR SAFE OPERATION 9 HOW TO DRAIN HEATER FOR FROST PROTECTION 10 TROUBLESHOOTING 11 WARRANTY 12 INSTALLER GENERAL INSTALLATION REQUIREMENTS 15 HEATER DIMENSIONS AND...

Страница 8: ...it the maximum temperature of the hot water to protect young children and elderly residents from scalding Compact Flue Your Rapid Continuous Flow water heater saves on installation space with a power...

Страница 9: ...eating may extinguish without warning To restart the heating open the tap further WARNING Do not touch the unit cover or flue outlet Do not insert objects into the flue outlet Steam may discharge on c...

Страница 10: ...t flow until water is hot enough This limits energy wastage On colder days steam may be seen coming out of the flue outlet This is normal for a gas water heater The heater will not operate if the elec...

Страница 11: ...emperatures In order to lower the hot water delivery temperatures to your bathroom and en suite or any other taps to a maximum of 50 C an approved temperature limiting device will be required to be fi...

Страница 12: ...to Re start heater after freezing conditions have passed 1 Re fit and tighten both drain plugs so they seal 2 Turn on the cold water supply at the isolation valves under heater 3 Turn on all hot water...

Страница 13: ...heater You can check if electricity and gas are turned on at their meters by turning on other appliances in the house that are connected to electricity or gas Hot water flow varies The heater is desi...

Страница 14: ...en water chemistry information should be sought from the supplier or it should be tested to ensure the water supply meets the requirements given in these guidelines for warranty to apply SATURATION IN...

Страница 15: ...SET OUT IN THE WATER HEATER WARRANTY HOWEVER THE FOLLOWING EXCLUSIONS MAY CAUSE THE WATER HEATER WARRANTY TO BECOME VOID AND MAY INCUR A SERVICE CHARGE AND OR COST OF PARTS a Accidental damage to the...

Страница 16: ...qualify to claim under this warranty you must a Be the owner of the water heater or have the owners consent to act on their behalf b Advise Alliance of defect without delay and within warranty period...

Страница 17: ...pipes must be sufficiently large to deliver the rated gas input for all gas appliances that are planned to be installed at the premises The Gas Installation Standard AS NZS 5601 sets out the method o...

Страница 18: ...ATER DIMENSIONS AND SPECIFICATIONS Heater Gas Type Hot Water Delivery L min 25oC Rise Delivery Tempera ture oC Min Max Water Supply Pressure Kpa Max Gas Input MJ hr Min Max Gas Inlet Pressure kPa Min...

Страница 19: ...n The heater can be installed recessed into a wall with a Wall Recess Box Kit The Wall Recess Box kit contains the instructions for this type of installation The flue terminal must be positioned so th...

Страница 20: ...5 1000 1000 1500 1500 1500 1000 1500 1500 1500 1500 1500 150 150 1000 1000 j k From any other flue terminal cowl or combustion air intake Horizontally from an openable window doo mechanical air inlet...

Страница 21: ...heater and insulate pipework if location is subject to freezing PRESSURE LIMITING VALVE if required PLV must not have non return valve characteristics or prevent reverse flow HOT OUTLET This unit is f...

Страница 22: ...LY as in series solar boosters However the delivery temperature can be 75 C or more depending on the maximum stored water temperature of the solar hot water system REFER TO AS NZS 3500 4 AND ANY LOCAL...

Страница 23: ...ater delivery pipe sizes must be large enough to ensure adequate flow for each outlet and appliance that will be connected Refer to the heaters technical specifications and local regulatory authority...

Страница 24: ...e heater The gas supply may then be connected to the heater with a disconnection union at the heater and an isolation valve See Diagrams showing Typical Installations Note Ensure the heater the isolat...

Страница 25: ...as pipe work for leaks Check hot water flow and confirm pre set delivery temperature 1 Plug in the water heater at the power outlet and switch on the electrical supply 2 Open a hot tap 3 The water hea...

Страница 26: ...llow 5V red J14 Flow meter Return Return Return 12V J9 Combustion fan Tacho signal Return 5V tacho supply 36V max variable 31VAC yellow 31VAC yellow 11 5Vac white Centre tap black 11 5Vac white 36V Ce...

Страница 27: ...1 Close the gas isolation valve at the inlet to the water heater 2 Connect a manometer to the gas inlet test point on the gas connection fitting under the water heater 3 Open the gas isolation valve...

Страница 28: ...pressure test point on the burner manifold SEE Diagram 5 Turn on electrical and gas supply 6 Press max gas switch FOR AT LEAST ONE SECOND This will ensure max water FLOW AND THEREFORE MAX GAS CONSUMP...

Страница 29: ...SUFFICIENT UNIT WILL REDUCE GAS CONSUMPTION AND GIVE WRONG PRESSURE The test switch is located as shown on PCB Board The burner high fire pressure adjustment is a 10mm brass nut as shown REMOVE PLASTI...

Страница 30: ...IA WILL NOT BE RESPONSIBLE FOR ANY SERVICE COSTS IF THIS GAS SUPPLY IS FOUND TO BE OUTSIDE STATED LIMITS IF HEATER CANNOT BE CORRECTLY ADJUSTED OR DOES NOT FUNCTION PROPERLY CONTACT ALLIANCE SERVICE F...

Страница 31: ...ance Appliances 26LPM Certificate holder Alliance Appliances Australia P L Manufactured by INTEK China Certificate number AGA 8059 G Date of issue of specification 06 Sept 2013 Page 29 Alliance Applia...

Страница 32: ...m 1000 Gas Rate Min Max Mj NG 15 199 Flow Rate 25 Degrees C Rise L min 26 Star Rating 5 1 Connection Sizes Gas Hot 20 BSPm or flat union Connection Sizes Gas Cold 20 BSPm or flat union Dimensions mm H...

Страница 33: ...aximum 1000 Gas Rate Min Max Mj PG 15 199 Flow Rate 25 Degrees C Rise L min 26 Star Rating 5 1 Connection Sizes Gas Hot 20 BSPm or flat union Connection Sizes Gas Cold 20 BSPm or flat union Dimensions...

Страница 34: ...144 Cochranes Road Moorabbin VIC 3189 T 0438 397 143 E geoff allianceappliances com au www allianceappliances com au...

Отзывы: