© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
31
802702
After the dryer has operated for approximately five
minutes, observe burner flame through lower front
panel. Adjust the air shutter to obtain a soft, uniform
blue flame. (A lazy, yellow-tipped flame indicates lack
of air. A harsh, roaring, very blue flame indicates too
much air.) Adjust the air shutter as follows:
1. Loosen the air shutter lockscrew.
2. Turn the air shutter to the left to get a luminous
yellow-tipped flame, then turn it back slowly to
the right to obtain a steady, soft blue flame.
3. After the air shutter is adjusted for proper flame,
tighten the air shutter lockscrew securely.
4. Reinstall the lower front panel.
After the dryer has operated for approximately three
minutes, exhaust air or exhaust pipe should be warm.
For personal safety, lower front panel must
be in place during normal operation.
W046
WARNING
D700I
DRY2235N
1
Closed Position
5
1/8 in. (3.1 mm) Pipe Plug
2
Shut-Off Valve Handle
(For checking manifold pressure)
3
Air Shutter Lockscrew
6
Open Position
4
Air Shutter
1
4
3
6
2
5
MODELS THROUGH SERIAL NO. 0803
1
4
3
6
2
5
MODELS STARTING SERIAL NO. 0804