© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
F8208801
50
Production Test Cycle Quick Reference Chart
Display
Test Cycle Step
Comments
“
S xx
”
FEC Control Software
Version
xx is the software version number.
“
o xx
”
Output Board Software
Version
xx is the software version number.
“
Ct 3
”
Control Type
xx is the control type.
“
oPL
”
Control Type
OPL.
“
USA
”
Control Type
Domestic
“
drAn
” or “
PUnP
”
Drain Type
Drain or Pump.
“
tEnP
”
Temp Sensor
Step skipped if not Temperature Sensor-equipped.
“
HEAt
”
Heater
Step skipped if not heater-equipped.
“
rot
”
Rotation Sensor
Step skipped if not Rotation Sensor-equipped.
“
L dC
”
or
“
L AC
”
Door Lock Type
“
L dC
”
if 24 VDC lock or “
L AC
”
if 240 VAC unlock solenoid.
“
droP
” or “
drCL
”
Door Status
Door open or closed.
“
drUL
”
or
“
drLo
”
Door Lock Status
Door will lock.
“
8.8.8.8.
” + all LEDs
Display Test
All display elements are lit.
“
PAxx
” where xx = 1
through 12
Keypad Test step
Advance after all keypads are pressed.
“
A xx
”
Top Cover Switch Test
xx is either “
CL
” for closed or “
oP
” for open.
“
Cxxx
” or “
Pxxx
”
Machine Type/Size
“
drxx
”
Drive Software Version
Number
xx is the drive software version number. Design 4 models only.
“
dPxx
”
Drive Parameter Table
Version Number
xx is the drive parameter table version number. Design 4 models
only.
“
dt x
”
Drive Type Value
xx is the drive type value. Design 4 models only.
“
HFIL
”
Hot Fill to Low Level
All water outputs turned off when Low Level reached.
“
CFIL
”
Cold Fill to Low Level
All water outputs turned off when Low Level reached.
“
bFIL
”
Warm Fill to Low Level
All water outputs turned off when Low Level reached.
“
bFIH
”
Warm Fill to High Level
All water outputs turned off when High Level reached.
“
S1
”
Supply #1
“
S2
”
Supply #2
“
S3
”
Supply #3
“
S4
”
Supply #4
Table 16 (continued)