Testing Machine and Electronic Control Functions
51
F8208801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: On models equipped with a rotation sensor,
“
xxx
” will represent RPM’s and it will alternate
with the other display.
Table 16 (continued)
Production Test Cycle Quick Reference Chart
Display
Test Mode
Comments
“
oFLo
”
Warm Fill to Overflow
“
xxxF
”
degrees F or
“
xxxC
” degrees C
depending on the
Fahrenheit/Celsius
programming parameter
Heat water to 110°F or display
temperature
xxx
is degree temperature. This step skipped if not temp-
sensor-equipped. Heater turned off when temperature reached.
“
LoAg
”
then
“
xxx
”
Reduced Wash Speed Forward
with no agitation action
This step skipped on 2 Speed models.
“
Ag
”
then
“
xxx
”
Wash Speed Forward with no
agitation action
“
rAg
”
then
“
xxx
”
Wash Speed Reverse with no
agitation action
“
drAI
”
then
“
xxx
”
Drain Distribution Speed
“
PUrg
”
Factory Valve Purge
“
SP 1
”
then
“
xxx
”
Extract Speed #1 “very low”
This step skipped on 2 Speed models.
“
SP 2
”
then
“
xxx
”
Extract Speed #2 “low”
This step skipped on 2 Speed models.
“
SP 3
”
then
“
xxx
”
Extract Speed #3 “medium”
This step skipped on 2 Speed Design 1 and 2 models and
L-Speed Design 4 models.
“
SPIn
”
(2 Speed models)
then
“
xxx
”
This step skipped on VFD models.
“
Prdn
”
End of test
Turn Power off
Table 16
Содержание UWL035K12