15
Operation
F232087
The following table lists the various displays
and what they mean. The operator should
become familiar with these computer displays.
Display Indications
Display
Meaning
Display
Meaning
S04
Program identification code (ROM)
This is an example only.
FLUS
Overflow prewash selected.
Hold
Wait...power has just been turned on.
CFIL
Cold fill
CY
Cycle (followed by two-digit number)
bFIL
Warm fill (both hot and cold)
CHEC/CYC* Test cycle selected.
HFIL
Hot fill
FAr
Degrees Fahrenheit
LOLE
Low water level
CEL
Degrees Celsius
HILE
High water level
PrE
Prewash segment (1st of 8 segments)
SUP1
Supply 1
UASH
Wash segment (2nd of 8 segments)
SUP2
Supply 2
FIL1
First rinse (3rd of 8 segments)
SUP3
Supply 3
FIL2
Second rinse (4th of 8 segments)
SUP4
Supply 4
FIL3
Third rinse (5th of 8 segments)
SUP5
Supply 5 (supply 1 and 2)
FIL4
Fourth rinse (6th of 8 segments)
SUP6
Supply 6 (supply 2 and 3)
FIL5
Fifth rinse (7th of 8 segments)
SUP7
Supply 7 (supply 3 and 4)
FIL6
Sixth rinse (8th of 8 segments)
StOP
Stop routine
SRIN
Spray rinse
SdLY
Spin coast delay
dRIN
Dilution rinse
donE
Cycle and stop routine have ended.
PrEU
Normal prewash selected.
door
Door not properly closed.
SPIn/tInE*
Reads “SPIn” for one second, then
“tInE” followed by time for spin.
FILL/StOP*
Programmed water level not reached after
30 minutes.
tSFL
Temperature sensor failure or temperature
out of range.
FULL
The computer detects low water level or
higher when none should be present.
*Display indications separated by a slash represent an alternating display.