Diagnostic Test Descriptions
Control Software Version Number Test
This option displays the control software version number. To start
test, control must be in the Testing Mode. Refer to “How to Enter
Testing Feature” at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
S xxx
where
xxx
is the software version number.
To enter, press the START (enter) keypad. The display will show
S XXX
where
XXX
is the software version number.
To exit the Software Version Number Test, press the MED TEMP
(<) keypad. The control will return to the testing mode.
Input/Output Board Software Version Number Test
This option displays the input/output board software version
number. To start test, control must be in the Testing Mode. Refer
to "How to Enter Testing Feature" at the beginning of this sec-
tion.
To enter, press the START (enter) keypad. The display will show
obxx
where
xx
is the software version number.
To enter, press the START (enter) keypad. The display will show
ob XXX
where
XXX
is the software version number.
To exit the Software Version Number Test, press the MED TEMP
(<) keypad. The control will return to the testing mode.
Service Door Opening Test
This option tests the service door switch. To start test, control
must be in the Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
S oP
when the service door switch is open and
S CL
when the
service door switch is closed.
The service door switch has to be closed for at least one second
and opened for at least a half a second to make a valid count.
This test will add counts to the service door opening counter for
the audit and save the date/time for each opening of the test.
To exit the Service Door Opening Test, press the MED TEMP (<)
keypad. The control will return to the testing mode.
Coin Vault Opening Test
This option tests the coin vault switch. To start test, the control
must be in the Testing Mode. Refer to
at the beginning of this section.
To enter, press the START (enter) keypad. The display will show
U oP
when the coin vault switch is open and
U CL
when the
coin vault switch is closed.
To enter, press the START (enter) keypad. The display will show
v oP
when the coin vault switch is open and
v CL
when the
coin vault switch is closed.
The coin vault switch has to be closed for at least one second and
opened for at least a half a second to make a valid count. This test
will add counts to the coin vault opening counter for the audit and
save the time/date for each opening of the test.
To exit the Coin Vault Opening Test, press the MED TEMP (<)
keypad. The control will return to the testing mode.
Coin Drop #1 Input Test
This option tests coin drop #1. To start test, control must be in the
Testing Mode. Refer to
ginning of this section.
To enter, press the START (enter) keypad. The display will show
C1xx
. The
xx
will show the number of coins entered and will in-
crement one for each coin entered in coin drop #1.
NOTE: Coins entered in test mode will not increment
the total # of coins counter that is accessed in the audit
feature.
To exit the Coin Drop #1 Input Test, press the MED TEMP (<)
keypad. The control will return to the testing mode.
Coin Drop #2 Input Test
This option tests coin drop #2. To start test, control must be in the
Testing Mode. Refer to
ginning of this section.
To enter, press the START (enter) keypad. The display will show
C2xx
. The
xx
will show the number of coins entered and will in-
crement one for each coin entered in coin drop #2.
NOTE: Coins entered in test mode will not increment
the total # of coins counter that is accessed in the audit
feature.
To exit the Coin Drop #2 Input Test, press the MED TEMP (<)
keypad. The control will return to the testing mode.
Start Pulse Test
This option tests the Start Pulse. To start test, control must be in
the Testing Mode. Refer to
beginning of this section.
To enter, press the START (enter) keypad. The display will show
Stxx
. The
xx
will show the number of pulses entered. This test
will add counts to the total number of Start Pulses counter.
To exit the Start Pulse Test, press the MED TEMP (<) keypad.
The control will return to the testing mode.
Factory Test Cycle
To Enter Factory Test Cycle
1. Be certain control is in Ready Mode, and service door or coin
vault is open.
2. While pressing and holding the HIGH TEMP keypad with
one hand, press the LOW TEMP keypad with the other hand.
Testing Machine and Electronic Control Functions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
35
Part No. D515810ENR3