Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
IMPORTANT: When reinstalling motor and
exhaust assembly, be sure wire harness on right side
is clipped to motor mounting bracket and is routed
along dryer base (between motor mounting bracket
and right side of cabinet). Refer to Figure 27. Tab on
rear of motor mounting bracket must be slid into
slot in dryer base. Be sure the belt has been installed
on the correct side of the idler lever. Refer to
Figure 28.
i. Motor pulley and idler pulley assemblies
(1) Refer to Figure 29 for motor and idler
pulley removal.
j. Impeller and housing
(1) Remove screw holding ground wire (if
present) to exhaust fan cover. Refer to
Figure 27.
NOTE: Ground wire must be routed as shown in
Figure 2 (Refer to Section 4, Grounding).
(2) Remove screws holding cover to housing.
Figure 29
DR044-SV-1
SETSCREW
MOTOR
PULLEY
TRU-ARC
RING
IDLER
PULLEY
IDLER
SPRING
GROUND
WIRE
MOTOR
CLAMP
MOTOR
SWITCH
Figure 30
DR045-SV-1
EXHAUST HOUSING
ATTACHING SCREWS