18
505872
Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NO SLIDE INPUT “S”
NOTE:
1. Vertical slides required for correct operation of computerized AUDIT slide input.
2. Coin chute must be clear of any obstructions (i.e.; coins, foreign material, etc.)
USE MICROWAND MAINTENANCE
PROGRAM TO TEST SENSOR BOARD.
ADVANCE COUNT BY COIN SLIDE INSERTION
CHECK COUNT “S”
SENSOR AUDIT
BOARD CHECKS
(SEE NOTES
ABOVE)
CHECK WIRING
1. CHECK CONNECTION OF RS1 TO HS1
(FIGURE 1)
2. CHECK CONTINUITY:
a) RS2 PIN 4 TO RS1 PIN 1
b) RS2 PIN 7 TO RS1 PIN 2
c) RS2 PIN 3 TO RS1 PIN 3
SEE FIGURE 1
REPLACE AUDIT
SENSOR BOARD
CORRECT WIRING
OR REPLACE AUDIT
WIRE HARNESS
RECHECK SLIDE INPUT
USE MICROWAND MAINTENANCE PROGRAM
TO TEST SENSOR BOARD.
ADVANCE COUNT BY COIN SLIDE INSERTION
CHECK COUNT “S”
REPLACE AUDIT
CONTROL BOARD
YES (COUNT INCREMENTED)
YES
NO
NO