32
505872
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
26. CONTROL HOOD – METERED AND NON-
METERED MODELS
a. Remove two control panel attaching screws and
lift assembly off cabinet top. Refer to Figure 7.
b. Disconnect all wires to temperature switch,
PUSH-TO-START switch and INDICATOR
LIGHT and remove ground clip and screw
holding ground wire to cabinet top and control
panel, Figure 5. (Refer to appropriate wiring
diagram when reconnecting wires.)
c. Metered Models: (Refer to Figure 10)
(1) Insert key in service door lock on top of
meter case and unlock door.
(2) Lift rear end of service door approximately
45° off meter case to disengage notched
tabs with internal rib at top of meter case.
NOTE: When reinstalling service door and
accumulator, front end of door must be inserted at
about a 45° angle in order to engage notched tabs
with internal rib at top of meter case.
d. Non-metered models: (Refer to Figure 8)
(1) Remove four screws and lockwasher
holding timer and plate to timer case.
NOTE: When reinstalling timer plate, lockwasher
must be between head of screw and plate.
(2) Pull timer and plate out of timer case as far
as wires will permit.
e. Remove cap screw holding control hood to
meter case. Refer to Figure 7.
f. Remove two screws holding control hood to
cabinet top and lift hood off rear tabs, Figure 7.
27. CONTROL HOOD - CARD READER
MODELS
Refer to Figure 7
a. Remove panel lock (if present)
NOTE: Several turns of the key may be required to
remove panel lock.
b. Remove two control panel attaching screws and
lift assembly off cabinet top.
c. Cut wires from card reader control at the butt
splice connector, remove strain relief and pull
wires through rear of hood.
NOTE: The butt splice connector will need to be
replaced during reinstallation.
d. Remove two screws holding control hood to
cabinet top and lift hood off rear tabs.
28. CONTROL HOOD REAR COVER
a. Refer to Figure 7 for removal.
NOTE: The control hood rear cover is welded to the
control hood on card reader models and is not
removable.
29. SERVICE DOOR, ACCUMULATOR AND
COUNTER –METERED MODELS
Refer to Figure 10
a. Insert key in service door lock on top of meter
case and unlock door.
b. Lift rear end of service door approximately 45°
off meter case to disengage notched tabs with
internal rib at top of meter case.
NOTE: When reinstalling service door and
accumulator, front end of door must be inserted at
about a 45° angle in order to engage notched tabs
with internal rib at top of meter case.
c. Disconnect accumulator wires at connectors.
NOTE: Refer to appropriate wiring diagram when
reconnecting wires.
d. Remove hex head ground screws holding green
ground wire to accumulator mounting bracket.
e. Remove two Phillips head screws and
lockwashers holding accumulator to mounting
bracket.
f. Counter (if present):
(1) Disconnect wire from terminal on
accumulator switch “C”.
(2) Cut other wire at butt splice connector.