Installation
21
512681
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Three-Wire Plug
Figure 21
To Convert from 4-Wire Connection to 3-Wire
Connection
1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.
Figure 22
D816I
1
3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)
4
Metallic or Non-Metallic Sheathed Cable
(
Copper wire only
)
5
Pigtail to Dryer (Refer to NOTE above)
2
30 Ampere Fuses or Circuit Breaker
6
Neutral
Wire
3
Neutral
Wire
7
Terminal Block in Dryer
NOTE: The power cord (pigtail) is NOT supplied with the electric
dryer. Type of pigtail and gauge of wire must conform to local
codes and instructions.
The method of wiring the dryer is optional and subject to local
code requirements.
NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.
1
2
3
4
5
6
7
POWER SUPPLY
POWER SUPPLY
INTERMEDIATE
FUSE BOX (May
be omitted if
service entrance
box is fused)
WALL RECEPTACLE
PIGTAIL CONNECTION
L1
L2
L1
L2
DIRECT CONNECTION
INTERMEDIATE
SHUT-OFF BOX
(May or may
not be fused)
120 ± 12
V.A.C.
A typical
30-Amp
Three-wire
Receptacle
NEMA Type
10-30R
120 ± 12
V.A.C.
240 ± 12
V.A.C.
NOTE: Use COPPER WIRE only.
Shorter than 4.5 m (15’) use 10 A.W.G.
Longer than 4.5 m (15’) use 8 A.W.G.
D695I