Vending
512681
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table 6 (continued)
Models Starting Serial No 0909
Test Setting
When testing coin slide operation or other
troubleshooting, set dipswitch with this shorter cycle:
1. Unplug the machine power cord.
2. Record the machine control dipswitch settings.
Then set them all to the off position. Refer to
Figure 29
.
3. Plug in the machine and initiate a cycle.
NOTE: With all the control dipswitches off, the
total cycle time will be four minutes long.
4. Once all the testing is complete, unplug the
machine and re-set the dipswitches to their
original settings.
5. Plug in the machine.
Figure 29
Cool Down Per Cycle
Cool Down
Switch Number
Cycle Reset
Switch Number
(in minutes)
7
8
3 (preset at factory)
OFF
OFF
6
ON
ON
Total Cycle Time = Heat Time + Cool Down Time
Table 6
DRY2225P
DRY2225P
1 2 3 4 5 6 7 8
O