Installation
9
512681
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installing the Dryer
Step 1: Position and Level the Dryer
Install dryer before washer. This allows room for
attaching exhaust duct.
Install the four rubber feet (in accessories bag).
Select a location with a solid floor. Dryers installed in
residential garages must be elevated 46 cm (18 inches)
above the floor.
No other fuel burning appliance should be installed in
the same closet with the dryer.
The dryer must not be installed or stored in an area
where it will be exposed to water and/or weather.
The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown in
Figure 3
).
D337I
1
Closet Door
2
Centered Air Openings (G) (2 Openings minimum)
3
Outer Wall of Enclosure
**NOTE: For new installations, locate top of wall vent 106.7 cm (42 inches) above floor to make venting
easier to connect.
Figure 3
D337I
1
2 (G)
3
A
E
**106.7 cm
(42 in.)
F
F
B
A
A
C
FRONT VIEW
(w/o Closet Door)
SIDE VIEW
(Closet Door)
FRONT VIEW
(Closet Door)
D
Area
Description
Free Standing/Alcove
Installation
Closet Installation
A
Dryer sides and rear clearance
0 cm (0 in.)
0 cm (0 in.)
B
Dryer top clearance
30.5 cm (12 in.)
30.5 cm (12 in.)
C
Dryer front clearance
Not Applicable
5.1 cm (2 in.)
D
Exhaust duct clearance to combustible material 5.1 cm (2 in.)
5.1 cm (2 in.)
E
Weather hood to ground clearance
30.5 cm (12 in.)
30.5 cm (12 in.)
F
Distance from floor or ceiling to hole edge
Not Applicable
7.6 cm (3 in.)
G*
Area of centered air openings in closet door
Not Applicable
260 sq. cm/open (40 sq. in.)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)