P118 Repeater to Repeater Link Port
P118 is used for the
Repeater to Repeater Link feature (R2R net).
P118 is a 5 pole male connector located to the right in the cabinet,
adjacent to the P124 connector (see
The P118 and P124 ports are identical an connected in series. One of the
connectors are intended to be used from the previous repeater in the net
chain, and the other connetor to the next repeater in the net chain.
Either of P118 or P124 can be used for the first and the last repeater in
the net chain.
Use straight connection between P118 and P124 connectors.
No termination is required for the outermost repeaters in an R2R net.
P112 PC Port
PC port P112 is a RS-232 port used for local PC communication.
P112 is a 9 pole D-sub female connector located to the right in the cabinet
(see
Connector pinning
Pin 1
Not used
Pin 2
Data from repeater to OMT32
Pin 3
Data from OMT32 to repeater
Pin 4
DTR from OMT32 to repeater
Pin 5
GND
Pin 6
DSR from repeater to OMT32
Pin 7
RTS from OMT32 to repeater
Pin 8
CTS from repeater to OMT32
Pin 9
Not used
P113 Parking Device
P113 is a parking device for a jumper used for the P130 port. The jumper
is used to interconnect pin 1 and pin 2 of the P130 port when there is no
RCC remote communication control unit connected to the repeater.
When an RCC unit is connected to the repeater, then the jumper can be
placed in P113.
P113 is an unconnected 2 pole male connector located to the right in the
cabinet, adjacent to the P130 connector (see
1
5
6
5
9
1
ALLGON Systems AB
ALR Compact Repeater
Installation
VD203 67/EN - User’s Manual
Rev. 1A 2000-07
3 - 10