ID
Alarm Text
OMS
Ceasing
Alarm Unit Alarm Level
Description
11
Log memory fault
No
BSC
Error
Log memory fault.
Indicates that the log memory on the BSC board is faulty. The
repeater will not work. Not available in all BSC software
versions.
12
High temperature
No
BSC
Warning
The BSC board temperature is higher than 90°C.
Ceasing
The BSC temperature has fallen below 90°C.
13
REFO error
Yes
BSC
Error
Low level from REFO is detected.
15
CU battery fault
No
BSC
Warning
BSC RAM battery fault.
The battery for the RAM on the BSC board has a voltage
outside the normal 2.7 to 3.5 Volt. An alarm may be initiated at
start-up if the repeater has been stored out of power for a long
time.
Suggested remedy: Ensure the jumper on the BSC board is
mounted to charge the battery.
Ceasing
The alarm criteria has ceased.
16
SW load error
No
BSC
Error
Software load error.
An error has occurred during a software load process. The flash
memory does not contain a proper software.
Suggested remedy: Check the BSC software using the OMT32
software manager. Do NOT restart the repeater.
17
Log cleared
No
BSC
None
Log memory has been cleared.
The check sum in the
Events list memory is faulty. The log is
cleared. Can be caused by a bad RAM battery backup or low
voltage to the RAM.
18
RTC restarted
No
BSC
None
The time is changed by the operator (logged to keep track of
changes made to the RTC).
Warning
Time reset to 1994-01-01.
The RTC was unable to keep track of the time did a reset.
Suggested remedy: Ensure the jumper on the BSC board is
mounted to charge the battery.
19
RTC error
No
BSC
Error
RTC does not operate.
The BSC has detected an error in RTC operation which makes
the time unreliable.
Suggested remedy: Replace the BSC board.
20
Door open alarm
No
External
Configurable The door has been open more than 30 seconds without
disabling the alarm. EAL4 alarm.
Ceasing
The door has been closed more than 30 seconds, or the alarm
is disabled.
Warning
The door has been open more than 30 seconds without
disabling the alarm. P120 connector alarm.
Ceasing
The door has been closed more than 30 seconds, or the alarm
is disabled.
21
External alarm 1
No
External
Configurable External alarm input EA1 active more than 1 second.
Ceasing
External alarm input EA1 no longer active.
22
External alarm 2
No
External
Configurable External alarm input EA2 active more than 1 second.
Ceasing
External alarm input EA2 no longer active.
23
External alarm 3
No
External
Configurable External alarm input EA3 active more than 1 second.
Ceasing
External alarm input EA3 no longer active.
24
External alarm 4
No
External
Configurable External alarm input EA4 active more than 1 second.
Ceasing
External alarm input EA4 no longer active.
30
No modem found
No
Remote ctrl
None
No modem found, i.e. no answer is returned on a poll string to
the modem.
ALLGON Systems AB
ALR Compact Repeater
Repeater Alarms
VD203 67/EN - User’s Manual
Rev. 1A 2000-07
7 - 3