SPN
Code
FMI
Code
Fault Check Description
Fault Detection Condition
Possible
Causes
20238
14
Diagnostic Fault Check to Report "WDA/
ABE Active" due to unknown reason
In the case of a non active shut-off path test (MoCSOP_stActMsg ==
FALSE) whose debounce OCWDA_CTDEBSOPNOTACTV* 10ms has
expired (counter OCWDA_ctDebSOPNotActv = 0) and an active ABE wire
due to undervoltage there is an undebounced defect detection after the
battery voltage BattU_u keeps greater than OCWDA_uBattMin_C (8V)
longer than the debounce time OCWDA_CTUBATTMX (100ms).
ECU Internal Fault
20251
11
Visibility of Software Resents in DSM
The evaluation of the reset reason will be done after every reset. De-
pending on the configured visibility of the current reset one of the fault
checks in the array will be set.
20
The evaluation of the reset reason will be done after every reset. De-
pending on the configured visibility of the current reset one of the fault
checks in the array will be set.
21
The evaluation of the reset reason will be done after every reset. De-
pending on the configured visibility of the current reset one of the fault
checks in the array will be set.
20276
11
Diagnostic Fault Check to Report the
Remote Accelerator Pedal Position Error
Implausible accelerator pedal voltage. The two voltage values (ADC_
VAL1, ADC_VAL2), detected by the accelerator pedal, are not plausible to
each other. If RMTAPP with LIS is used , defect is detected if there is a
implausibilty with LIS and RMTAPP1 voltage.
20282
3
Short Circuit to Battery on Out1 Error for
H-Bridge
Short Circuit to Battery at Out1 of TLE7209/CJ230 Error
Wiring Harness or
Component
Short Circuit to Battery on Out2 Error for
H-Bridge
Short Circuit to Battery at Out2 of TLE7209/CJ230 Error
4
Short Circuit to Ground on Out1 Error for
H-Bridge
Short Circuit to Ground at Out1 of TLE7209/CJ230 Error
Short Circuit to Ground on Out2 Error for
H-Bridge
Short Circuit to Ground at Out2 of TLE7209/CJ230 Error
5
Open Load Error for Power-stage
Open Load Error Monitoring for TLE7209/CJ230
12
Over Temperature Error for H-Bridge
Over Temperature Error Monitoring for TLE7209/CJ230
Wiring Harness
Component for
ECU Internal Fault
20288
2
DFC for Coding Error when Different
Coding Words were Received in a cod-
ing cycle
Glowing Problems
No Load Error for Low Voltage System
3
Short Circuit to Battery Error for Low
Voltage System
4
Short Circuit to Ground Error for Low
Voltage System
5
Over Temperature Error on ECU Power-
stage for Glow Plug Low voltage System
14
DFC for T30 Missing Error in GCU-T
21
DFC for Coding Error when Selected
Coding is not working
22
DFC for faulty Diagnostic Data
Transmission or Protocol Error
23
DFC for glow Module Error in GCU-T
Fault Codes
SECTION 3
SERVICE
069971
Page 50