Rockwell Automation Publication 20B-IN019E-EN-P - July 2013
15
PowerFlex 700 Adjustable Frequency AC Drive – Frames 0…6
Frame 5 – IP54, NEMA Type 12 Flange Mount (400…690V drives only)
Fram
e
Description
Approx. Weight
(1)
kg (lbs.)
(1) Weights include HIM and Standard I/O.
Drive
Drive & Packaging
5
Flange Mount
61.69 (136.0)
81.65 (180.0)
303.6
(11.95)
2.3 (0.09)
Compressed
Gasket
97.0
(3.82)
384.0 (15.12)
42.0 (1.65)
1061.0
(41.77)
1039.0
(40.91)
11.0 (0.43)
500.0 (19.69)
478.0 (18.82)
5.5 (0.22) Dia. x 40
12.7 (0.50) Dia. Lifting Holes x 4
Air
Outlet
11.0 (0.43)
53.2
(2.09)
USE 75 C CU WIRE ONLY
WIRE RANGE: 4-3/0 AWG (18-70 MM2)
TORQUE: 133 IN-LB (15 N-M)
STRIP LENGTH: 1.02 IN (26 MM)
POWER & DC TERMINAL RATINGS
WIRE RANGE: 14-1/0 AWG (2.5-50 MM2)
TORQUE: 32 IN-LB (3.6 N-M)
STRIP LENGTH: 0.67 IN (17 MM)
BRAKE TERMINAL RATINGS
WIRE RANGE: 6-1/0 AWG (18-35 MM
2
)
TORQUE: 44 IN-LB (5 N-M)
STRIP LENGTH: 0.83 IN (21 MM)
GROUND TERMINAL RATINGS (PE)
OUTPUT
INPUT AC
300 VDC EXT PWR SPLY TERM (PS+, PS-)
WIRE RANGE: 22-10 AWG (0.5-4 MM
2
)
TORQUE: 5.3 IN-LB (0.6 N-M)
STRIP LENGTH: 0.35 IN (9 MM)
DANGER
DANGER
RISK OF ELECTRIC
SHOCK AND DEATH
FIELD INSTALLED OPTIONS
6 MM HEX KEY
6 MM HEX KEY
SHLD
SHLD
219.5 (8.64)
196.5 (7.74)
185.0
(7.30)
449.6
(17.74)
127.6
(5.02)
194.0
(7.60)
Ground
M5 PEM Nut
Dimensions are in millimeters
and (inches)