70
Rockwell Automation Publication 20B-IN019E-EN-P - July 2013
PowerFlex 700 Adjustable Frequency AC Drive – Frames 0…6
Running an Assisted Start Up
The Assisted start-up routine prompts you to input required information. Access
Assisted Start Up by selecting “Start Up” from the Main Menu.
To perform an Assisted Start-Up
Drive Status Indicators
IMPORTANT
This start-up routine requires an LCD HIM.
Step
Key(s)
Example LCD Displays
1. In the Main Menu, press the Up Arrow or
Down Arrow to scroll to “Start Up”.
2. Press Enter.
IMPORTANT
Done/Exit must be selected upon completion of the Start Up routine in order
for any Start Up/Autotune data to be saved.
Name
Color
State
Description
Green
Steady
Illuminates when power is applied to the drive.
Green
Flashing
Drive ready, but not running and no faults are present.
Steady
Drive running, no faults are present.
Yellow
Flashing, Drive
Stopped
An inhibit condition exists, the drive cannot be started. Check
parameter 214 [Start Inhibits].
Flashing, Drive
Running
An intermittent type 1 alarm condition is occurring.
Check parameter 211 [Drive Alarm 1].
Steady,
Drive Running
A continuous type 1 alarm condition exists.
Check parameter 211 [Drive Alarm 1].
Red
Flashing
A fault has occurred.
Steady
A non-resettable fault has occurred.
Refer to the Communication
Adapter User Manual.
Status of DPI port internal communications (if present).
Status of communications module (when installed).
Status of network (if connected).
Status of secondary network (if connected).
F-> Stopped
Auto
0.0
Hz
Main Menu:
Memory Storage
Start Up
Preferences
POWER
STS
PORT
MOD
NET A
NET B