3-10
Configuring the Adapter
To set an adapter to transmit Peer-to-Peer data
1.
Verify that
Parameter 41 - [Peer Out Enable]
is set to
Off
. This
parameter must be set to Off while you configure some of the peer
output parameters.
Figure 3.10 Peer Out Enable Screen on an LCD HIM
2.
Select the source of the data to output to the network in
Parameter
39 - [Peer A Output]
.
Figure 3.11 Peer A Output Screen on an LCD HIM
If you are transmitting a 32-bit Reference or 32-bit Datalink, only
Peer A Output will be available. Peer B Output cannot be used.
3.
If desired, select an additional source of the data to output to the
network in
Parameter 40 - [Peer B Output]
.
Figure 3.12 Peer B Output Screen on an LCD HIM
Value Setting
0
Off (Default)
1
On
Port 5 Device
20-COMM-D
Parameter #: 41
Peer Out Enable
0
Off
Port 5 Device
20-COMM-D
Parameter #: 39
Peer A Output
1
Cmd/Ref
Value
Description
0
Off (Default)
1
Logic Command/Reference
2 - 5
Datalink A, B, C, or D
Input
6 - 9
Datalink A, B, C, or D
Output
Port 5 Device
20-COMM-D
Parameter #: 40
Peer B Output
2
DL A Input
Value
Description
0
Off (Default)
1
Logic Command/Reference
2 - 5
Datalink A, B, C, or D
Input
6 - 9
Datalink A, B, C, or D
Output
Содержание PowerFlex 20-COMM-D
Страница 1: ...DeviceNet Adapter 20 COMM D FRN 1 xxx User Manual...
Страница 6: ...iv Table of Contents Notes...
Страница 72: ...6 14 Using Explicit Messaging Notes...
Страница 90: ...B 8 Adapter Parameters Notes...
Страница 122: ...C 32 DeviceNet Objects Notes...
Страница 132: ...E 8 Master Slave I O Configuration Notes...
Страница 148: ......