Data Manipulation Instructions
Chapter 6
619
BINARY
ADDR – 125
DATA – 111111111111
BCD
ADDR – The BCD number is stored in adjacent data table words 200
and 201
DATA – The industrial terminal will display 004095, the BCD
equivalent of the binary value for this example.
Figure 6.19
BinarytoBCD Conversion Format
BINARY TO BCD
BINARY
ADDR:
010
DATA:
000000000000
BCD
ADDR:
110- 111
DATA:
000000
010
(OV)
14
Numbers shown are default values. Bold numbers must be replaced by userentered values. The number of default address digits initially
displayed 3, 4, or 5 will depend on the size of the data table. Initially displayed default values are governed by the I/O rack configura
tion.
BINARY ADDR
: Stores the binary number.
BINARY DATA
: The 12 bits of the binary number.
BCD ADDR
: Address where the first three digits of the BCD number are stored. The second threedigit address is where the
three leastsignificant BCD digits are stored.
BCD DATA
: The BCD number that is equivalent to the 12 bits of the binary data block.
OV
: Overflow bit. Set high when binary number is > 12 ones or a decimal equivalent of 004095. It is in a word where
the binary word is to be stored.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com