1761-6.5
Application Examples
7-9
0004
B3:31
11
MOV
Move
Source
I:0.0
341<
Dest
N7:89
341<
MOV
MOV
Move
Source
I:0.1
0<
Dest
N7:80
0<
MOV
0005
N7:82
9
N7:82
12
N7:82
14
T4:38
DN
EN
DN
TON
Timer On Delay
Timer
T4:38
Time Base
0.01
Preset
100<
Accum
0<
TON
0006
END
0003
N7:82
13
B3:31
11
N7:82
12
U
N7:82
15
T4:38
DN
The rung is used to reset a completed or errored message instruction. Resetting the MSG instruction will re-arm it to
re-transmit.
MicroLogix to DNI Message Done Input Data has Changed Flag
MicroLogix to DNI Message Enabled
Message Error
Retry Message
If the input data has changed, set the input buffer (N7:80 and N7:89) equal to the inputs. This rung re-arms rung 0000
in this example.
Input Data has Changed Flag
This rung times the write message instruction for errors or lockup conditions. The timer restarts communications
whenever an error occurs. Lockup conditions are situations that may arise if the communications path is corrupted. For
example, power is lost at the destination device or a cable is cut. Error conditions are typically caused from noise on the
communications link or a faulty device on the network.
Retry Message
Retry Message
Message Started, NOT Completed
Message Error
Message Transmitting
Содержание DeviceNet 1761-NET-DNI
Страница 14: ...1761 6 5 P 6...
Страница 16: ...1761 6 5 1 2 Product Overview...
Страница 22: ...1761 6 5 2 6 Quick Start for Experienced Users...
Страница 34: ...1761 6 5 4 6 Installation and Wiring...
Страница 74: ...1761 6 5 6 16 Setup Programming and T roubleshootin g...
Страница 84: ...1761 6 5 7 10 Application Examples...
Страница 94: ...1769 6 5 A 4 Specifications...
Страница 99: ...1761 6 5 I 3 AB Parts...
Страница 100: ......