Publication 1756-UM001E-EN-P - August 2002
Communicate with a DeviceNet Device
16-3
J.
Is the module in a remote chassis?
K.
Initially, do you want the module to communicate with the
controller?
L.
If communication with the module fails, how do you want the
controller to respond?
M.
Click
Finish
.
If:
Then:
Yes
Type the rate at which the fastest device in the chassis must update.
•
Use a power of two times the ControlNet NUT.
•
For example, if the NUT is 5 ms, type a rate of 5, 10, 20 ms, etc.
No
Leave the RPI at the default setting.
If:
Then:
Notes:
Yes
Leave the check box cleared
(unchecked).
No
Select the check box.
When you test this portion of the
system, clear the check box.
ATTENTION
!
If communication with a module fails, the
controller operates on old data from the
module. To avoid potential injury or damage,
either monitor communications with modules
or configure modules to produce a major fault
if communications fail.
If you want the
controller to:
Then:
Notes:
fault (major fault)
Select the check box.
continue operating
Leave the check box
cleared (unchecked).
Monitor the connection
using ladder logic.
Содержание controllogix 1756-L63
Страница 1: ...ControlLogix System 1756 L1 L1Mx L55Mxx L63 User Manual Allen Bradley HMIs...
Страница 4: ...Publication 1756 UM001E EN P August 2002 Summary of Changes 2 Notes...
Страница 16: ...Publication 1756 UM001E EN P August 2002 Table of Contents x...
Страница 46: ...Publication 1756 UM001E EN P August 2002 2 4 Download and Go Online over an EtherNet IP Network Notes...
Страница 116: ...Publication 1756 UM001E EN P August 2002 6 16 Communicate with a PanelView Terminal Over a EtherNet IP Network Notes...
Страница 156: ...Publication 1756 UM001E EN P August 2002 8 16 Communicate with 1756 I O over a ControlNet Network Notes...
Страница 184: ...Publication 1756 UM001E EN P August 2002 9 28 Communicate with 1771 I O Over a ControlNet Network Notes...
Страница 200: ...Publication 1756 UM001E EN P August 2002 10 16 Communicate with 1794 I O Over a ControlNet Network Notes...
Страница 218: ...Publication 1756 UM001E EN P August 2002 11 18 Communicate with Another Controller over a ControlNet Network Notes...
Страница 222: ...Publication 1756 UM001E EN P August 2002 12 4 Route PLC 5 Messages Between ControlNet Networks Notes...
Страница 268: ...Publication 1756 UM001E EN P August 2002 15 4 Monitor Connections Notes...
Страница 276: ...Publication 1756 UM001E EN P August 2002 16 8 Communicate with a DeviceNet Device Notes...
Страница 306: ...Publication 1756 UM001E EN P August 2002 18 8 Route PLC 5 or SLC 500 Messages From a DH Network Notes...
Страница 368: ...Publication 1756 UM001E EN P August 2002 22 18 Configure DF1 Master and Slave Communications Notes...
Страница 402: ...Publication 1756 UM001E EN P August 2002 24 22 Program Motion Control Notes...
Страница 408: ...Publication 1756 UM001E EN P August 2002 25 6 Maintain the 1756 BA1 Battery Notes...
Страница 418: ...Publication 1756 UM001E EN P August 2002 B 2 Estimate Execution Time...
Страница 420: ...Publication 1756 UM001E EN P August 2002 C 2 Estimate Memory Use...
Страница 422: ...Publication 1756 UM001E EN P August 2002 D 2 Determine When Data Is Updated Notes...
Страница 424: ...Publication 1756 UM001E EN P August 2002 E 2 Reconfigure an I O module Notes...
Страница 428: ...Publication 1756 UM001E EN P August 2002 4 Index...
Страница 429: ...Publication 1756 UM001E EN P August 2002 Index 5 Allen Bradley HMIs...
Страница 430: ...Publication 1756 UM001E EN P August 2002 6 Index...
Страница 435: ...ControlLogix System User Manual Allen Bradley HMIs...