Publication 1756-UM001E-EN-P - August 2002
Communicate with Another Controller over an EtherNet/IP Network
5-3
Produce a Tag
A.
Open the RSLogix 5000™ project for the controller that produces
(sends) the data.
B.
From the
Logic
menu, select
Edit Tags
.
C.
From
Scope
, select
name_of_controller
(controller)
. (Only
tags that are controller scope can produce data.)
D.
Select the tag that will produce the data and press the
ALT + Enter
keys.
E.
Select the
Produced
option button.
F.
Type or select the number of controllers that will consume
(receive) the tag.
G.
Choose
OK
.
IMPORTANT
To produce a tag, the tag must meet be:
•
controller scope
•
one of these data types:
–
DINT
–
REAL
–
array of DINTs or REALs
–
user-defined
•
less than or equal to 500 bytes
If the tag does not meet these requirements,
reorganize the tag.
42352
Содержание controllogix 1756-L63
Страница 1: ...ControlLogix System 1756 L1 L1Mx L55Mxx L63 User Manual Allen Bradley HMIs...
Страница 4: ...Publication 1756 UM001E EN P August 2002 Summary of Changes 2 Notes...
Страница 16: ...Publication 1756 UM001E EN P August 2002 Table of Contents x...
Страница 46: ...Publication 1756 UM001E EN P August 2002 2 4 Download and Go Online over an EtherNet IP Network Notes...
Страница 116: ...Publication 1756 UM001E EN P August 2002 6 16 Communicate with a PanelView Terminal Over a EtherNet IP Network Notes...
Страница 156: ...Publication 1756 UM001E EN P August 2002 8 16 Communicate with 1756 I O over a ControlNet Network Notes...
Страница 184: ...Publication 1756 UM001E EN P August 2002 9 28 Communicate with 1771 I O Over a ControlNet Network Notes...
Страница 200: ...Publication 1756 UM001E EN P August 2002 10 16 Communicate with 1794 I O Over a ControlNet Network Notes...
Страница 218: ...Publication 1756 UM001E EN P August 2002 11 18 Communicate with Another Controller over a ControlNet Network Notes...
Страница 222: ...Publication 1756 UM001E EN P August 2002 12 4 Route PLC 5 Messages Between ControlNet Networks Notes...
Страница 268: ...Publication 1756 UM001E EN P August 2002 15 4 Monitor Connections Notes...
Страница 276: ...Publication 1756 UM001E EN P August 2002 16 8 Communicate with a DeviceNet Device Notes...
Страница 306: ...Publication 1756 UM001E EN P August 2002 18 8 Route PLC 5 or SLC 500 Messages From a DH Network Notes...
Страница 368: ...Publication 1756 UM001E EN P August 2002 22 18 Configure DF1 Master and Slave Communications Notes...
Страница 402: ...Publication 1756 UM001E EN P August 2002 24 22 Program Motion Control Notes...
Страница 408: ...Publication 1756 UM001E EN P August 2002 25 6 Maintain the 1756 BA1 Battery Notes...
Страница 418: ...Publication 1756 UM001E EN P August 2002 B 2 Estimate Execution Time...
Страница 420: ...Publication 1756 UM001E EN P August 2002 C 2 Estimate Memory Use...
Страница 422: ...Publication 1756 UM001E EN P August 2002 D 2 Determine When Data Is Updated Notes...
Страница 424: ...Publication 1756 UM001E EN P August 2002 E 2 Reconfigure an I O module Notes...
Страница 428: ...Publication 1756 UM001E EN P August 2002 4 Index...
Страница 429: ...Publication 1756 UM001E EN P August 2002 Index 5 Allen Bradley HMIs...
Страница 430: ...Publication 1756 UM001E EN P August 2002 6 Index...
Страница 435: ...ControlLogix System User Manual Allen Bradley HMIs...