Installation Instructions

Original Instructions

TLSZR/L-GD2 Guard Locking Switch

Catalog Numbers 440G-TZS21UPRH, 440G-TZS21UPLH, 440G-TZS21UTRH, 440G-TZS21UTLH

Table of Contents

Summary of Changes

Added 

Auxiliary Out Function on page 3

.

Installation Instructions

IMPORTANT

Do not attempt to install this device unless the installation 
instructions have been studied and understood. This 
installation instruction sheet is available in multiple languages 
at 

www.rockwellautomation.com/literature

IMPORTANT

Ne pas tenter pas d'installer ce dispositif sans avoir étudié et 
compris les instructions d'installation. Cette notice 
d'installation est disponible dans certaines langues sur le site 

www.rockwellautomation.com/literature

WICHTIG

Versuchen Sie nicht, dieses Gerät zu installieren, bevor Sie die 
Installationsanleitung gelesen und verstanden haben. Diese 
Installationsanleitung steht in mehreren Sprachen unter der 
folgenden Adresse zur 
Verfügung:

www.rockwellautomation.com/literature

IMPORTANTE

Non installare questo dispositivo senza prima avere letto e 
compreso le istruzioni per l'installazione.  Queste istruzioni per 
l'installazione sono disponibili per alcune lingue sul sito 

www.rockwellautomation.com/literature

IMPORTANTE

Não instale esse dispositivo sem estudar e compreender as 
instruções de instalação. Essa folha de instruções de instalação 
está disponível em algumas línguas em 

www.rockwellautomation.com/literature

.

IMPORTANTE

No instale este dispositivo sin estudiar y entender las 
instrucciones de instalación. Esta hoja de instrucciones de 
instalación está disponible en algunos idiomas en 

www.rockwellautomation.com/literature

.

Viktigt

Läs monteringsanvisningen innan försök att installera enheten 
görs. Detta instruktionsblad finns tillgängligt på olika språk på 

www.rockwellautomation.com/literature

Topic Page

Summary of Changes

1

Installation Instructions

1

Technical Specifications

2

OSSD Outputs and Pulse Testing

3

Connections

4

Status/Diagnostic LED Indicator

4

Commissioning

4

Dimensions [mm (in.)]

6

Mounting Information [mm (in.)]

7

Wiring Diagrams

8

Recommended Relays

10

Maintenance

10

Declaration of Conformity

10

IMPORTANT

SAVE THESE INSTRUCTIONS FOR FUTURE USE

Target

Actuator

TLSZR/L-GD2

Switch

Target

Alignment

Marks

Содержание 440G-TZS21UPLH

Страница 1: ...itivo senza prima avere letto e compreso le istruzioni per l installazione Queste istruzioni per l installazione sono disponibili per alcune lingue sul sito www rockwellautomation com literature IMPORTANTE Não instale esse dispositivo sem estudar e compreender as instruções de instalação Essa folha de instruções de instalação está disponível em algumas línguas em www rockwellautomation com literat...

Страница 2: ...TÜV Operating Characteristics TLSZR GD2 Power to Release TLSZL GD2 Power to Lock Assured Locking Distance mm in Maximum target distance 13 0 51 Maximum clearance between actuator base and switch in the door closed position 5 mm 0 2 in See Clearance in ClosedPosition mm in and Maximum Actuator Insertion Distance for Locking on page 3 Torque for M5 Mounting 1 4 Nm 12 39 lb in Torque for Cover Mounti...

Страница 3: ...ApproachDirections The actuator and target are always be mounted as close coupled and can approach the switch in any of the three entry slot positions shown Approach from the underside is not allowed Figure 1 Clearance in Closed Position mm in and Maximum Actuator Insertion Distance for Locking Provide a separate mechanical stop to protect the switch Minimum clearance 2 0 08 Maximum assured lockin...

Страница 4: ...ime learn consecutively four different targets and then complete a One Time learn that would help prevent it from learning any more targets Connections 8 Pin Micro M12 Color Function Pin 8 Pin Cordset 889D F8AB or cable version White Aux 1 Brown 24V DC 2 Green Lock 3 Yellow Safety B OSSD Input 4 Gray Safety A OSSD Output 5 Pink Safety B OSSD Output 6 Blue Gnd 0V 7 Red Safety A OSSD Input 8 Replace...

Страница 5: ...ect the 24V DC power to pin 2 The switch conducts a self testing regime at the end of which the diagnostic light emitting diode shows solid red 3 Test to confirm the machine cannot start 4 Confirm the lock control at pin 3 is set to 0V for PTR and 24V for PTL types 5 Test again to confirm the machine cannot start 6 Close the guard door and then confirm the guard is mechanically locked and the diag...

Страница 6: ...0 55 33 1 3 6 5 0 26 25 5 1 20 5 0 81 5 0 2 5 5 0 22 21 0 83 17 0 67 43 1 69 6 0 24 5 0 2 73 2 87 4 0 16 Status Diagnostic LED Target Alignment Mark 14 0 55 2 2 0 09 24 0 94 4 2 0 17 19 2 0 76 M12 18 0 71 20 0 79 8 0 31 40 1 57 31 4 22 6 8 0 27 4 x 5 5 0 22 2 x M3 19 0 75 13 0 51 51 2 0 52 2 05 Actuator Use with flexible actuator only 23 2 0 91 11 9 0 47 19 0 75 440G ATZAE xxxx 29 3 1 15 7 0 28 20...

Страница 7: ...ntingInformation mm in 1 2 N m 10 62 lb in 2 x M5 1 4 N m 12 39 lb in 3 x M5 15 0 59 Steel bolts Plastic pins Fzh 2000 N 450 lb Fzh 1500 N 337 lb 5 0 20 dia 2 x M5 1 4 N m 12 39 lb in 1 2 N m 10 62 lb in 5 5 0 22 6 0 24 20 0 79 86 5 3 4 35 1 38 40 1 57 13 0 51 19 0 75 6 0 24 7 0 28 180 Target Actuator ...

Страница 8: ...es inputs are 0V OSSDs are de energized to 0V Green LED is flashing to indicate series inputs are not 24V Actuator 5 is in sensing range and locked Switch 5 is functioning properly Series inputs are 0V OSSDs are de energized to 0V Green LED is flashing to indicate series inputs are not 24V OSSDs are OFF Target Actuator 1 Target Actuator 2 Target Actuator 3 Switch 1 Switch 2 Switch 3 RTN 24V DC Pow...

Страница 9: ... 2 3 4 5 6 7 8 9 RANGE 1 2 3 4 5 6 7 8 9 10 TIME Gry Pnk Brn Yel Red Blu Wht Aux TLSZR GD2 DI 440R D22R2 EMD 440R EM4R2D The safety function initiated by the E Stop meets the safety performance requirements of SIL CL3 per IEC 62061 2015 for Category 0 and has a Category 4 structure that can be used in systems requiring Performance Levels up to PLe per ISO 13849 1 2008 24V Class 2 Power Source M K1...

Страница 10: ... manual release which can indicate abuse or interference Check for damage which can cause loss of sealing at the lid or conduit entry If there is any malfunction or damage no attempts at repair can be made The unit must be replaced before machine operation is allowed DO NOT DISMANTLE THE UNIT DeclarationofConformity This product conforms to the Essential Health and Safety Requirements EHSRs of the...

Страница 11: ...Rockwell Automation Publication 440G IN016A EN P October 2017 11 TLSZR L GD2 Guard Locking Switch Notes ...

Страница 12: ...ve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Center Knowledgebase Articles How to Videos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate the phone number for your country http www rockwella...

Отзывы: