Controls and Connections
ADVANCED POWER SUPPLY TECHNOLOGY
DIGITAL SYSTEM BACKUP SUPPLY
POWER ON
POWER
ON
OFF
iPS10
ALLEN&HEATH
Made in the UK by ALLEN&HEATH LIMITED
SERIAL NUMBER
ALLEN&HEATH iPS10
BACKUP PSU
CONNECT ONLY TO
SPECIFIED A&H
DIGITAL EQUIPMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(2) this device must accept any interference received, including interference that may cause undesired operation.
(1) this device may not cause harmful interference, and
100 - 240V~
47-63Hz ~ 320W MAX
T5AL 250V
FUSE
20MM
MAINS INPUT
CHASSIS
GROUND
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE
ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
WITH SAME TYPE AND RATING. DISCONNECT SUPPLY BEFORE CHANGING FUSE.
DO NOT OPEN. NO USER SERVICEABLE PARTS INSIDE.
DO NOT OBSTRUCT VENTILATION OPENINGS.
THIS APPARATUS MUST BE EARTHED BY THE POWER CORD.
COUPER L'ALIMENTATION AVANT DE CHANGER LE FUSIBLE.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
POWER ON/OFF
Press to switch the
iPS10
power unit on or off. The
internal fan runs at
constant speed while the
unit is switched on.
POWER STATUS
The blue indicator lights at full brightness while the unit is
switched on and working correctly. If the indicator does
not light check that mains power is switched on and the
IEC mains cord properly inserted. If the indicator lights
at half brightness there may be a voltage rail fault. If this
is the case switch the unit off and contact your Allen &
Heath service agent.
DC POWER OUT
10-pin female socket to output the
5 DC voltage rails and 3 ground
connections. It also has two pins
for power status information. Plug
in the DC power cable supplied
with the unit. Do this by rotating
the male plug until the mating tabs
align with the socket, then insert
fully and tighten the locking screw
ring. Be careful not to cross
thread the screw ring.
TEMPERATURE MONITOR
RJ45 socket to output the temperature
status information to the iLive. Use the
CAT5 cable supplied with the unit. A
sensor monitors the temperature
inside the unit. The supply shuts down
safely if the internal temperature
reaches 85 degrees C. A fan inside
the unit prevents it running too hot.
MAINS INPUT
Plug in the IEC
mains cord supplied
with the unit. Make
sure it is inserted
fully and has not
been modified in
any way.
MAINS FUSE
To check or replace the fuse use a flat bladed
screwdriver or coin to push in and rotate the
fuse holder until it pops out. Always replace
with the correct type and value (T5AL 20mm
250V). In the event of repeated failure of the
mains fuse, consult your Allen & Heath service
agent.
GROUND POST
Chassis metal grounding
(earthing) post for attaching
a grounding wire to other
equipment or metal cases or
racks in the system if
needed. For best results
use heavy duty wire. Note
that the
iPS10
metalwork is
grounded via the mains
cord. Do not defeat this
connection.