iPS10

 User Guide 

The iPS10 Power Supply 

The slimline, 2U rack mountable 

iPS10

 power supply unit is a high performance, low noise, universal 

mains voltage, switched mode power supply producing the DC voltages required to run the iLive 
Surface or IDR0 MiniRack.  It is available as an option to provide redundant backup of the internal 
mains power supplies fitted in these iLive components.  The iLive will operate with either or both 
supplies switched on. 

Two connecting cables are required between the 

iPS10

 and iLive.  The power unit produces 5 

different DC voltages and has three independent ground connections.  These connect to the iLive via 
a 2.8 meter long multicore DC cable fitted with 10-pin circular locking connectors.  Voltage rail 
protection, thermal sensing and fan cooling ensure the power supply unit will operate consistently.  
The power unit temperature information connects to the iLive via a 2.8 meter long CAT5 cable.  
Current status may be viewed by the operator on the iLive Surface TouchScreen. 

 

Installation 

Free standing 

The 

iPS10

 can be operated as a freestanding unit for shelf or floor operation.  Check that its plastic 

feet are fitted.  Ensure adequate air flow around the unit.  It must not be covered in any way.  Always 
stand the unit on a firm flat surface away from any soft furnishings or carpet. 

Rack mounting 

The 

iPS10

 is designed as a 19 inch rack mount unit and will occupy 2U (3.5 inches) of rack space.  

The plastic feet may need to be removed before rack mounting.  Retain the feet for future use.  
Ensure natural convection of airflow around the unit by allowing good ventilation below, in front of 
and behind the unit.  Rack equipment known to produce a significant amount of heat should not be 
mounted directly below the power supply unit.  Forced convection by means of a rack mounted fan-
tray may be desirable in situations where space is restricted and the ambient air temperature is high. 

Cables 

The DC power and temperature monitor cables are 2.8 meters long to allow the unit to be positioned 
away from the console.  Make sure the cables are not stretched in any way and are routed to avoid 
becoming kinked or damaged.  Allow enough service loop for access and removal of the unit.  
Ensure all connectors are fully plugged in and locked. 

Consideration should be given to the earthing (grounding) arrangement of the system.  The iLive 
chassis is connected to the mains earth via the power supply unit.  Do not remove the IEC power 
cord earth connection.  A screw terminal chassis grounding post is provided on the rear of the 

iPS10

 

for situations where additional earth bonding is required. 

Dimensions 

 

Do not obstruct the ventilation 

slots.  Ensure adequate air flow around 
the iPS10. 

 

Ensure proper grounding.  Do not 

remove the IEC mains cord earth 
(ground) connection. 

 

Do not remove the cover of the 

iPS10.  There are no user serviceable 

parts inside.

 

310 mm / 12.2"

374 mm / 14.7"

443 mm / 17.4"

2U

88 

mm / 3

.46

"

482 mm / 19"

Содержание iPS10

Страница 1: ...ALLEN HEATH Digital Console Backup Power Supply iPS10 USER GUIDE Publication AP6688 ADVANCED POWER SUPPLY TECHNOLOGY DIGITAL SYSTEM BACKUP SUPPLY POWER ON POWER ON OFF iPS10 ALLEN HEATH...

Страница 2: ...erformance and reliability for which this equipment has been designed and manufactured read this User Guide before operating In the event of a failure notify and return the defective unit to ALLEN HEA...

Страница 3: ...e ground connection in the power cord Water and moisture To reduce the risk of fire or electric shock do not expose the power supply unit to rain or moisture or use it in damp or wet conditions Do not...

Страница 4: ...y objects on the unit scratching the surface with sharp objects or subjecting the power supply unit to rough handling and vibration Environment Protect from excessive dirt dust heat and vibration when...

Страница 5: ...serial number and date and place of purchase to be quoted in any communication regarding this product The serial number is located on the rear panel Check the Packing Contents Retain the product packi...

Страница 6: ...inch rack mount unit and will occupy 2U 3 5 inches of rack space The plastic feet may need to be removed before rack mounting Retain the feet for future use Ensure natural convection of airflow aroun...

Страница 7: ...heck that mains power is switched on and the IEC mains cord properly inserted If the indicator lights at half brightness there may be a voltage rail fault If this is the case switch the unit off and c...

Страница 8: ...ITOR CABLE DC CABLE IEC MAINS CABLES CAT5 10way MAINS INTERNAL PSU Surface CPU power on Internal PSU on Backup PSU on Mains power 100 240V AC Female plug Male plug Cable retention clip iPS10 BACKUP PS...

Страница 9: ...ule at the rear of the iLive surface light to indicate that the power supplies are switched on and working correctly There is one for the internal surface supply and one for the backup supply The iPS1...

Страница 10: ...number 003 576 Temperature cable 2 8m CAT5 RJ45 A H part number AH6831 Protection Under voltage detection and thermal sensing Cooling Fan assisted Thermal shutdown at 85 degrees C Installation 2U rac...

Отзывы: