background image

iPS10

 User Guide 

Important Safety Instructions 

WARNINGS

  -  Read the following before proceeding : 

ATTENTION: RISQUE DE CHOC ELECTRIQUE – NE PAS OUVRIR 

 

Read instructions

:

 

Retain these safety and operating instructions for future reference.  Adhere to 
all warnings printed here and on the power supply unit.  Follow the operating 
instructions printed in this User Guide. 

Do not remove covers

:

  Operate the power supply unit with its covers correctly fitted.  Refer any 

service work on the power supply unit to competent technical personnel only. 

Power sources

:

  

Connect the power supply unit to a mains power supply only of the type 
described in this User Guide and marked on the rear panel.  Use only the 
power cord with sealed mains plug appropriate for your local mains supply 
as provided with the power supply unit.  If the provided plug does not fit into 
your outlet consult your service agent for assistance. 

Power cord routing

Route the power cord so that it is not likely to be walked on, stretched or 
pinched by items placed upon or against it. 

Grounding

:

 

Do not defeat the grounding and polarisation means of the power cord plug.  
Do not remove or tamper with the ground connection in the power cord. 

 

 

 

 

Water and moisture

:

  

To reduce the risk of fire or electric shock do not expose the power supply 
unit to rain or moisture or use it in damp or wet conditions.  Do not place 
containers of liquid on it which might spill into any openings.  

Ventilation

:

  

Do not obstruct the ventilation slots or position the power supply unit where 
the air flow required for ventilation is impeded.  If the power supply unit is to 
be operated in a flightcase ensure that it is constructed to allow adequate 
ventilation. 

Heat and vibration

:

 

Do not locate the power supply unit in a place subject to excessive heat or 
direct sunlight as this could be a fire hazard.  Locate the power supply unit 
away from any equipment which produces heat or causes excessive 
vibration. 

Servicing

:

    

Switch off the equipment and unplug the power cord immediately if it is 
exposed to moisture, spilled liquid, objects fallen into the openings, the 
power cord or plug become damaged, during lightening storms, or if smoke, 
odour or noise is noticed.  Refer servicing to qualified technical personnel 
only. 

Installation

:

    

Install the power supply unit in accordance with the instructions printed in this 
User Guide.  Do not connect the output of power supply unit to any other 
equipment other than that specified by Allen & Heath. 

 

CAUTION

  WARNING:  This equipment must be earthed. 

Содержание iPS10

Страница 1: ...ALLEN HEATH Digital Console Backup Power Supply iPS10 USER GUIDE Publication AP6688 ADVANCED POWER SUPPLY TECHNOLOGY DIGITAL SYSTEM BACKUP SUPPLY POWER ON POWER ON OFF iPS10 ALLEN HEATH...

Страница 2: ...erformance and reliability for which this equipment has been designed and manufactured read this User Guide before operating In the event of a failure notify and return the defective unit to ALLEN HEA...

Страница 3: ...e ground connection in the power cord Water and moisture To reduce the risk of fire or electric shock do not expose the power supply unit to rain or moisture or use it in damp or wet conditions Do not...

Страница 4: ...y objects on the unit scratching the surface with sharp objects or subjecting the power supply unit to rough handling and vibration Environment Protect from excessive dirt dust heat and vibration when...

Страница 5: ...serial number and date and place of purchase to be quoted in any communication regarding this product The serial number is located on the rear panel Check the Packing Contents Retain the product packi...

Страница 6: ...inch rack mount unit and will occupy 2U 3 5 inches of rack space The plastic feet may need to be removed before rack mounting Retain the feet for future use Ensure natural convection of airflow aroun...

Страница 7: ...heck that mains power is switched on and the IEC mains cord properly inserted If the indicator lights at half brightness there may be a voltage rail fault If this is the case switch the unit off and c...

Страница 8: ...ITOR CABLE DC CABLE IEC MAINS CABLES CAT5 10way MAINS INTERNAL PSU Surface CPU power on Internal PSU on Backup PSU on Mains power 100 240V AC Female plug Male plug Cable retention clip iPS10 BACKUP PS...

Страница 9: ...ule at the rear of the iLive surface light to indicate that the power supplies are switched on and working correctly There is one for the internal surface supply and one for the backup supply The iPS1...

Страница 10: ...number 003 576 Temperature cable 2 8m CAT5 RJ45 A H part number AH6831 Protection Under voltage detection and thermal sensing Cooling Fan assisted Thermal shutdown at 85 degrees C Installation 2U rac...

Отзывы: