S
PECIFICATION
7
S
ONG
M
EMORIES
127 User programmable memories and the
PAUSE
patch each store:
Default
Name
8 Characters
SONG
n (1-127)
Lock
Off or On Prevents song memory from being overwritten
Off
Mute
MUTE
off (channel on) or
MUTE
on (channel off)
CH1-8, FX1, FX2, AUX, FB, LR
EQ1 to 8
4-band parametric channel equaliser
HF
+/-15dB shelving Sweep from 2kHz to 20kHz
HM
+/-15dB bell peak/dip Sweep from 500Hz to 15kHz
Q (width) = 0.2, 0.3, 0.8, 1.7 octave
LM
+/-15dB bell peak/dip Sweep from 35Hz to 1kHz
Q (width) = 0.2, 0.3, 0.8 1.7 octave
LF
+/-15dB shelving Sweep from 20Hz to 200Hz
-15dB switches to 12dB/octave high pass filter (
HPF
)
Sweep from 20Hz to 200Hz
OUT
= EQ switched in or out of circuit
0dB 8kHz
0dB 2kHz
0.8 octave
0dB 250Hz
0.8 octave
0dB 63Hz
Compressor
DRIVE
control = How much compression
Combines ratio, threshold, make-up gain
From Off > gentle compression > hard compression
26 steps from 0 (off) to 25 (max) range:
Ratio 1:1 (off) to 16:1 (hard compression)
Threshold –20dB to -10dB
Make-up gain 0dB to 9dB (hard compression)
ATTACK
= How fast the compressor responds
RELEASE
= How fast the compressor releases
25 steps from 1 (fast) to 25 (slow)
Attack 0.3mS to 300mS
Release 100mS to 10S
KNEE
= How sharp the turning point on the gain curve
Hard or soft
Off
13
S (soft)
Gate
LEVEL
= Threshold level at which the noise gate opens
26 steps from off, -72dB to 0dB
ATTACK
= How fast the gate opens as the threshold is reached
25 steps from 1 (0.1mS) to 25 (2S)
DECAY
= How fast the gate closes
25 steps from 1 (200mS) to 25 (2S)
Off
7
13
icon
SERIES
7 - 1
Содержание DL1000
Страница 1: ...ALLEN HEATH USER GUIDE Publication AP3299 ...
Страница 8: ...CONNECTING THE SYSTEM mains viii icon SERIES ...