5 Further information for initial operation
© 2022 Interflex Datensysteme GmbH | IF-5835 Time Recording Terminal | 07.22
17
4. Reset switch position:
Associated console command:
factory-reset full
5.2 Users and passwords
The default user is
fieldservice
. A dialog is presented after the first login to specify the
password for this user.
u
Login to the controller and specify the password
Prerequisites for a valid password
n
Minimum 8 characters in length
n
Contains upper and lowercase letters and numbers
If one of these features is missing, the minimum length is extended by 2 digits.
n
Does not contain mutated vowels, special characters or sequences of characters (e.g. "aaa")
n
Does not contain the default password
After four consecutive incorrect entries, the entry is blocked for 25 seconds.
5.3 Log files of the CloudReady controller
Two services of the CloudReady controller write their output in log files:
n
cloudreadyd
n
service-app-mgr
The log files are located in the
/home/fieldservice/app/log
folder.
Name conventions
The log files of both services are named according to the following convention:
<service-name>-<controller-hostname>.log
In the factory state, the host name corresponds to the controller’s serial number. Changes to
the host name are only adopted in the file name of the log files after the services have been
restarted.