![Allegion Interflex IF-572x Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/allegion/interflex-if-572x/interflex-if-572x_technical-manual_2898400020.webp)
14
Maintenance and Service
File name
Command
tctermfwup.bat
tctermfwup.bat <terminal firmware file> <IP address
controller>
The terminal number is hard-coded in the batch file, e.g.:
sh% -pw %ctrl_password% root@%2 "%dest_bin_dir%/etp
1
-fun %1
Updates to multiple controllers are performed individually for each one. To
do so, open the batch file in an editor and change the number of the
controller.
tcswup.bat
tcswup.bat <TC software file> <IP address controller>
5.12 Performing device license upgrade
The functional scope of a device is dependent upon the purchased license. You can expand (upgrade)
this license.
Example: Upgrade from an IF-5725 terminal to IF-5735:
After you have ordered the upgrade, Interflex will send you:
The batch file
tclicence.bat
The license file named
if5735-00403755-2016-05-21.xml
.
Meaning of the name:
The new file is of type
if5735
.
The serial number is
00403755
.
The file was created on
2016-05-21
.
Performing upgrade
Start
cmd.exe
and run batch file:
File name
Command
tclicence.bat
tclicence.bat <License file> <IP address controller>
The license is automatically copied to the right location in the controller.
The license is activated.
A restart of the application is initiated.
6 Maintenance and Service
The device IF-57xx does not require any regular maintenance.
Use an off-the-shelf glass or plastic cleaning agent for cleaning. For touch displays, we recommend using
methylated spirit or an anti-bacterial cleaning agent for plastic materials.
Do not use cleaning agents that contain benzine or solvents.
Conduct the device tests prescribed by law.
6.1 Unplugging the RJ45 connector
The key on the RJ45 connector faces the wall.
To disconnect the cable, force the connector's key upwards with a small screwdriver.