Maintenance and Service 

 

File name

 

Command

 

tctermfwup.bat

 

tctermfwup.bat <terminal firmware file> <IP address 
controller>

 

The terminal number is hard-coded in the batch file, e.g.: 

sh% -pw %ctrl_password% root@%2 "%dest_bin_dir%/etp 

1

 

-fun %1

 

Updates to multiple controllers are performed individually for each one. To 
do so, open the batch file in an editor and change the number of the 
controller. 

tcswup.bat

 

tcswup.bat <TC software file> <IP address controller>

 

 

 

5.12  Performing device license upgrade 

The functional scope of a device is dependent upon the purchased license. You can expand (upgrade) 
this license. 

Example: Upgrade from an IF-5725 terminal to IF-5735: 

After you have ordered the upgrade, Interflex will send you: 

 

The batch file 

tclicence.bat

 

 

The license file named 

if5735-00403755-2016-05-21.xml

Meaning of the name:   

 

The new file is of type 

if5735

 

The serial number is 

00403755

 

The file was created on 

2016-05-21

Performing upgrade 

  Start 

cmd.exe

 and run batch file: 

 

File name

 

Command

 

tclicence.bat

 

tclicence.bat <License file> <IP address controller>

 

 

 

The license is automatically copied to the right location in the controller. 

 

The license is activated. 

 

A restart of the application is initiated. 

 

6  Maintenance and Service 

The device IF-57xx does not require any regular maintenance. 

Use an off-the-shelf glass or plastic cleaning agent for cleaning. For touch displays, we recommend using 
methylated spirit or an anti-bacterial cleaning agent for plastic materials. 

Do not use cleaning agents that contain benzine or solvents. 

  Conduct the device tests prescribed by law. 

 

6.1  Unplugging the RJ45 connector 

The key on the RJ45 connector faces the wall. 

  To disconnect the cable, force the connector's key upwards with a small screwdriver. 

 

Содержание Interflex IF-572x

Страница 1: ......

Страница 2: ......

Страница 3: ...manual which is subject to change without prior notice Interflex Datensysteme GmbH does not enter into any commitment Copyright 2017 Version Date July 26 2017 Interflex Datensysteme GmbH Allegion Zett...

Страница 4: ......

Страница 5: ...the Device 7 4 1 Risk of electric shock 7 4 2 Electrostatic discharge ESD 7 4 3 Reader electronics to PoE terminal board 8 4 4 Power supply 8 4 5 Service interface 9 5 Configuring the Device 9 5 1 Con...

Страница 6: ...ii Contents 7 Accessories Overview 15 8 Technical Specifications 15 8 1 EU Declaration of Conformity 16 8 2 Open source program packages 16 9 Disposal 16...

Страница 7: ...tions described in this document if you belong to this target group 1 3 Symbols used in this document Warnings warn against hazards that may arise when using the devices described in the document The...

Страница 8: ...is device in environments exposed to explosion hazards 1 6 All specifications are subject to change without notice All information contained in this documentation is accurate at the time of printing A...

Страница 9: ...handles functions of the time recording access control program writes offline NetworkOnCard data onto credentials Allows for connection of an I O controller board optional additional hardware required...

Страница 10: ...18 70 52 and temporarily store the specified IP address 8 Adhesive tape Is applied over the mortise lock to prevent electrostatic discharges 9 Reset button Ends active processes and triggers a reboot...

Страница 11: ...contacts control cable 100 m JY ST Y 2 x 2 x 0 6 mm RS 485 bus cable to parent or child devices 1 200 m JY ST Y 2 x 2 x 0 6 mm RS 485 branch cable to bus cable 100 m JY ST Y 2 x 2 x 0 6 mm Cable lengt...

Страница 12: ...a positive decision a booking response and or a signal for activating an output relay for example are transmitted to the booking location If the decision is negative the reason for the booking rejecti...

Страница 13: ...strain relief if necessary The device must be connected via an external separator to ensure that it can be disconnected from the mains power supply The device must be equipped with an external fuse pr...

Страница 14: ...using the supplied ribbon cable as shown 4 4 Power supply Power can be supplied via PoE device IEE 802 3 of power class 3 up to 13 W and RJ 45 cable 18 to 24 VAC VDC power supply unit The RJ45 cable...

Страница 15: ...onnection Use the factory set IP address see label on housing or the IP address 172 18 70 52 via the RS 232 service interface and the Hyper Terminal software Access to the console and Linux commands i...

Страница 16: ...no netpar s reboot system netpar y enable DHCP netpar y print this screen 5 4 1 Setting network parameters netpar x The command netpar x shows you the current network parameters e g the IP address and...

Страница 17: ...e allows 8 terminals as maximum Explanation for devices of the IF 1xxx series Term Description host baud rate 1 1 200 2 9 600 3 19 200 Token ring baud rate Baud rate TCP IP network 0 4 MB 1 16 MB Baud...

Страница 18: ...shbox I O I O controller boards of the slave terminals The characters mean 1st First I O controller board for door control is ready for operation 2nd Second I O controller board I O extension board is...

Страница 19: ...files are available File name Purpose setpathvars bat You require this file for all updates You can enter the system password here in order to make it invisible in cmd exe You can also change the pat...

Страница 20: ...if5735 00403755 2016 05 21 xml Meaning of the name The new file is of type if5735 The serial number is 00403755 The file was created on 2016 05 21 Performing upgrade Start cmd exe and run batch file F...

Страница 21: ...sion Interface expander Order Number Item 75 5735 0003 Interface expander for I O expansion 8 Technical Specifications Electrical Data Power Supply 18 to 24 VAC VDC PoE device IEE 802 3 of power class...

Страница 22: ...ysically performing source distribution Interflex offers to provide you with a medium customarily used for software interchange containing a complete machine readable copy of the source code of the pr...

Отзывы: