4
System Overview
2.2 Sockets, LEDs and switches
No.
Designation
Function
1
Anti-tamper switch Triggers an alarm when the housing is opened. To suppress this alarm, it must be
turned off by a parameter setting in the time recording program.
2
USB port
WLAN connection
3
phyCore board
Device control
4
2x Ethernet LEDs
Light up to indicate live network connection
5
Application LED
Lights up as soon as the system processes are activated and the device is ready.
6
Power LED
Lights up when operating voltage is switched on.
7
DIP switches
The cold boot switch (1) is used to delete stored data and set default parameters.
The SW switch (2) is used to set the default IP address 172.18.70.52 and temporarily
store the specified IP address.
8
Adhesive tape
Is applied over the mortise lock to prevent electrostatic discharges.
9
Reset button
Ends active processes and triggers a reboot (restart).
2.3 Touch screen
For optimal use of the touch screen, remove the protective film from the display before using the
device for the first time.
The touch screen has a layer that detects small electrical discharges, such as those emitted by the
human body.
Touch the screen with your fingertip to perform a booking.
The touch screen does not respond when touched with a sharp object such as a stylus.
Make sure that the touch screen does not come into contact with other electrical equipment.
Electrostatic discharges may cause malfunctions.
Make sure that the touch screen does not come into contact with liquids. Moisture or contact with
liquids may cause malfunctions.