background image

Questions?/Des questions?/¿Preguntas? 1-800-334-6871 [email protected]

1

Instruction Manual/Manuel d’instructions/Instrucciones

PACKAGING CONTENTS/CONTENU DE L’EMBALLAGE/CONTENIDO DEL PAQUETE

CAUTION

•  Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids 

the warranty.

•  Fixture should be installed by persons with experience in household wiring or by a 

qualified electrician. The electrical system, and the method of electrically connecting 

the fixture to it, must be in accordance with the National Electrical Code and local 

building codes.

•  Mount fixture to a grounded, recessed-mounted standard junction box marked for use 

in wet locations.

•  Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
•  Do not allow sensor head to touch light housing – maintain at least 

1 in. space between fixture and sensor.

•  For proper operation and protection against damage, the motion sensor head 

adjustment knobs must be facing the ground.

•  Keep away from flammable objects. Do not position fixture within 2 in.

of any combustible materials.

•  Always replace bulb with the same wattage or lower wattage 

than marked. Installing a bulb of a higher wattage could create a  

fire hazard. Use of a higher wattage bulb will void the warranty (maximum 150 watt 

halogen bulb). To meet ENERGY STAR

®

 requirements, maximum lamp wattage cannot 

exceed 250 watts.

•  MINIMUM 90°C SUPPLY CONDUCTORS.
•  This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and (2) 

this device must accept any interference received, including interference that may cause 

undesired operation. Under Part 15   of the FCC Rules, any changes or modifications to 

the motion detector described in this instruction sheet that are not expressly approved 

by Eaton could void the user’s authority to operate the equipment.

NOTE:

 This equipment has been tested and found to comply with the limits for a  

Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are  

designed to provide reasonable protection against harmful interference in a residential 

installation. This equipment generates, uses and can radiate radio frequency energy 

and if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference  

will not occur in a particular installation. If this equipment does cause harmful  

interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one 

or more of the following measures:

-  Reorient or relocate the receiving antenna.

-  Increase the separation between the equipment and receiver.

-  Connect the equipment into an outlet on a circuit different from that to which the  

  receiver is connected.

-  Consult the dealer or an experienced radio/TV technician for help.

 

WARNING: FCC Regulations state that any unauthorized changes or 

modifications to this equipment not expressly approved by the manufacturer  

could void the user’s authorization to operate this equipment.

SAVE THESE INSTRUCTIONS.

ITEMS REQUIRED

 

(Purchase separately)

•  Phillips screwdriver
•  Drill with 3/16 in. drill bit (only needed if hole pattern 

on coverplate does not match junction box)

•  Outdoor weatherproof silicone caulking
•  (2) 100 watt (MAX) PAR 38 floodlight bulbs

NOTE:

 For improved energy efficiency, lower wattage PAR  

halogen flood bulbs may be used. Compact Fluorescent (CFL)  

bulbs contain electronics which may interfere with the motion sensing function of your 

fixture and are not recommended. To meet ENERGY STAR

® 

requirements, maximum 

lamp wattage cannot exceed 250 watts.

HOW IT WORKS

Your motion activated floodlight senses heat images from 

objects such as people, large animals and automobile engines. 

When motion is detected, the lights will automatically turn 

on. Once motion has stopped, the lights will turn off after a 

preselected time delay. Your motion activated floodlight may 

also be used as a standard floodlight.

IMPORTANT SAFETY INSTRUCTIONS

  When using product, basic precautions should always be followed, including the following:

•  Heed all warnings, including below warnings AND those included on product.
•  Save these instructions and warnings.
•  For outdoor use only.
•  cULus LISTED for wet location.
•  Disassembly of your fixture will void the warranty.
•  Your fixture is prewired and preassembled for easy installation.

•  Read and follow these instructions.
•  Risk of fire/electric shock. If not qualified, consult an electrician.
•  To reduce the risk of a burn during relamping, disconnect power supply to the unit 

before relamping.

•  Bulb gets HOT quickly! 
•  Disconnect power and allow fixture to cool before changing bulb or handling fixture.
•  Disconnect power at fuse or circuit breaker before installing or servicing.

A.

  Motion detector 

  and light fixture
  Luminaire avec détecteur de 
 mouvement
  Detector de movimiento 
  y accesorio

 ENGLISH

Up to

70 feet

180 degrees

B.

 (2) Lampholder gaskets 

  (2) joints statiques pour douille
  (2) Juntas obturadoras 

    del receptáculo

C.

  (2) #6 and (2) #8 mounting screws 

   (use the size that fits your junction box)
   (2)  vis nº 6 et (2 )vis nº 8 pour boîte de jonction

  

(choisissez la dimension convenant à votre   

   boîte de jonction)
   (2) Tornillos #6 y (2) tornillos #8 de montaje

  

(utilice el tamaño que mejor se adecue a 

   su caja de conexión) 

 

D.

   (3) Wire nuts

   (3) capuchons de connexion
   (3) Conectores del cables 

WARNING

MS185

 

(Bronze/Bronce)

MS185W

 

(White/Blanco)

Содержание MS185

Страница 1: ...one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different...

Страница 2: ...ours 6 Set dial to desired time setting The higher the time setting the longer the lamps will be on Maximum time is 12 minutes SELECTING YOUR DESIRED FEATURE Mode of Operation MODE Knob Adjustment How...

Страница 3: ...luminaire est c bl et assembl pour faciliter son installation Lisez et suivez ces instructions Risque d incendie ou de d charge lectrique Si vous n avez pas les comp tences n cessaires faites appel u...

Страница 4: ...tecteur jusqu l obtention des r sultats souhait s REMARQUE Pour une port e maximale faites fonctionner l appareil d clairage dans un mode quelconque sous tension pendant au moins 48 heures 6 R glez l...

Страница 5: ...ur La commande au bas du d tecteur de mouvements est en mode TEST essai Modifiez le r glage du bouton autre que le mode TEST essai Le d tecteur de mouvements est ombrag Modifiez la position du d tecte...

Страница 6: ...nte neutral alternativa se debe utilizar en caso que la caja de conexi n no es de metal y la casa no tiene alambre de tierra 4 Sujete el accesorio a la caja de conexiones con los dos tornillos C Ya se...

Страница 7: ...xtiende s lo para el comprador original del producto Un recibo de compra u otra prueba de la fecha de compra original aceptable para Eaton Esto es necesario para la ejecuci n de la garant a Esta garan...

Отзывы: