W 3 S E R I E S
H I G H P R E S S U R E A I R C O M P R E S S O R
©ALKIN COMPRESSORS
15
moisture separator and sends it over the 4 drain valves forcing them to close. When the solenoid is de-energised, it
removes the control air over the top of the drain valve pistons, allowing the high pressure acting from the bottom of
the pistons, to open and perform drain operation.
Electric Motor
W3 Series of compressors can be driven by electric motor. They are belt-driven. They have an hourmeter which
shows the working hours of the unit on the control panel on W3 Canopy models.
Radiator, Intercoolers and Aftercooler:
These interstage and afterstage cooling serpentines and tubes are designed to dissipate the heat generated from
the previous compression cycle, reducing the air temperatures. There are radiators at the first two stages. IT IS
UNNECESSARY TO REPLACE RADIATOR, INTERCOOLERS AND AFTERCOOLER UNLESS
THEY ARE WORN, CRACKED OR BROKEN.
Purifier:
This is the filtration system that purifies the compressed air to prodcue clean air. Air compressed in the compressor
stages finally enters the purifier. A refillable cartridge which contains the consumables performing the filtration is
placed in the purifier housing. Refillable cartridges are more cost effective and environtment friendly compared to
replacable cartridges. Consumables inside the cartridge removes the oil, odour and water condensate from the
compressed air. After that clean air leaves the purifier to be given to the hoses or system. The purifier has a check
valve at its inlet and a priority valve at the discharge. Consumables inside the Purifier Cartridge should be replaced
periodically to have clean air comply with Breathing Air Standards at the discharge. Condensate collected inside the
Purifier Housing should be drained manually twice a day or after each filling process.
Prefiltre:
This filtration system, which filters the particles and oil in the compressed air right before the purifier, has
stainless steel housing and disposable filter cartridges. Its refillable cartridge must be replaeced at every 300
hrs maximum. During the first replacement, check the used cartridge’s condition and adjust the replacement
intervals accordingly.
Check valve:
It does not let the compressed air inside the purifier goes back to the stages and protects the compressor to run under
back pressure.
Содержание W3 Series
Страница 1: ...W3 SERIES HIGH PRESSURE AIR COMPRESSORS...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 5...
Страница 14: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 9...
Страница 26: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 21...
Страница 30: ...W 3 S E R I E S H I G H P R E S S U R E A I R C O M P R E S S O R ALKIN COMPRESSORS 25...