Ventilation of cylinder compartments for cylinders exceeding 1.25KG gas capacity:
Cylinder compartments shall have permanent openings ventilating directly to the outside of the
appliance, and consisting of either-
(a) Perforations, uniformly distributed over the height of the enclosure and with a total free area
of not less than 25% of the sidewall area; or
(b) Separate openings at high and low level, such that-
(i) The total free area at high level is not less than 20,000 square mm and is within 125 mm of
the top of the cylinder compartment; and
(ii) The total free area at low level is not less than 20,000 square mm and-
(A) At least 25% of the required area is within 15 mm of the base of the cylinder
compartment;
(B) The total required area is within 125 mm of the base of the cylinder compartment; and
(C) The openings cannot be obstructed by the cylinder.
When used on the ground always place the cylinder on flat level ground.
NEVER light the BARBEQUE with the HOOD in the closed position.
Storage of Appliance
Storage of this appliance indoors is only permissible if the gas cylinder is disconnected and
removed from the appliance. When the appliance is not to be used for a period of time it should
be stored protected from the elements in a dry dust free environment.
This barbeque is designed for use outdoors only, away from any flammable materials. It is
important that there are no overhead obstructions within 120 cm above the unit. It is important
that the ventilation openings of the appliance are not obstructed. The barbeque must be
installed on a level, stable, heat resistant surface. The appliance should be protected from
direct draughts and shall be positioned or protected against direct penetration by any trickling
water (e.g. rain).
Parts sealed by the manufacturer must not be altered by the user. No modifications should be
made to any part of this barbeque and repairs and maintenance should only be carried out by
an authorised service technician.
Connection to Appliance
Before connection, ensure that there is no debris caught in the head of the gas cylinder,
regulator, burner and burner ports. Spiders and insects can nest within and clog the
burner/venturi tube at the orifice. A clogged burner can lead to a fire beneath the appliance.
Clean burner holes if necessary with a heavy-duty pipe cleaner.
Disconnect the regulator from the gas cylinder when the barbeque is not in use. Do not
disconnect the hose at the barbeque. If the hose is replaced, fit the new hose to the appliance
using two spanners (one to hold the connection firm, the other to tighten the hose onto the
connection). Check for leaks.
Refer to page 10 and onwards for more details on gas connections.
Where to put your barbeque (continued)