Example 2: three-step
Set the POWER START 1 = 20%
START POWER 2 = 30%,
START POWER 3 = 50%,
START TIME 1 = 3 seconds,
START TIME 2 = 3 seconds,
START TIME 3 = 3 seconds,
MAX POWER = 100%.
This means that the rotator starts with 20% power, within 3 seconds
power reaches 30%, followed by 3 seconds during which power reaches 50%
and the last 3 seconds in which power reaches 100%.
Page 35 of 55 AlfaSpid_MD-01-02_12APR2022.odt
Copyright
Alfa Radio Ltd. 2022