Inputs terminal block (X3) 

The inputs are optoinsulated and compatible with clean contact signals or 24 VDC PNP transistor 
outputs. 

Name 

Terminal 

Default 

Input  0 

X3.1 

START 

Input 8 

X3.2 

 

Input 1 

X3.3 

T.D.C.(1) 

Input 9 

X3.4 

 

Input 2 

X3.5 

 

Input 3 

X3.6 

 

Input 4 

X3.7 

 

Input 5 

X3.8 

 

Input 6 

X3.9 

 

Input 7 

X3.10 

 

0VDC 

X3.11 

Negative power supply 

+24VDC 

X3.12 

Positive power supply 

(1) T.D.C. input in always on input 1. 

The function of each input is configurable. Each input can have one of the following functions: 

Name 

Default 

Function 

START 

Request for starting a new cycle. If remove the acquisition is stopped. 

T.D.C.(1) 

Signal "top dead center", used as a reset for a new cycle and ANDed with 
the zero mark of the encoder to the zeroing the absolute position 

JOB SELECTOR 

 

The binary value of these inputs select automatically a jobs (see 2). 

PHASE SELECTOR 

 

The binary value of these inputs select automatically the phase of job. 

BASKET 1 

Input for sensor for the detection of normal rejected (basket) 

BASKET 2 

Input for sensor for the detection of special rejected (basket) 

BASKET AUTO-CHECK 

 

Input for sensor for the detection of auto-check samples (basket) 

RESET 

Re-enable the instrument after a rejected 

SESPEND ACQUIRE 

 

Suspends the acquisition of the curve useful in hydraulic presses in case 
of stop in halfway. 

ENABLE # 

 

See 2.4 

TEST SIGNAL # 

#1=4 

See 2.4 

BOOSTER CYL BACK 

 

Used for the repetition of the working stroke 

BOOSTER CYL END 

 

Used for the repetition of the working stroke 

MAINTENANCE 

Disable all controls 

TABLE IN POS 

 

Signal for piece in the working position 

IMPULSIVE START 

Left=6 

Right=7 

Request for start of a new cycle 

NO EMERGENCY 

 

Machine is not in emergency 

SAFETY 

 

Machine security (guards closed) 

DRIVER ATIVATE 

 

Driver actived (servo presses) 

IN POSITION 

 

Position reached (servo presses) 

(1) T.D.C. input in always on input 1. 

Содержание CSQ-Visual

Страница 1: ...Mar 7 2017 CSQ Visual Version with VIO9 card Installation manual...

Страница 2: ...2...

Страница 3: ...of the instrument 4 1 3 Internal cards 5 1 4 Electric wiring 5 2 Special functions 12 2 1 Configure automatic work selection 12 2 2 Configuring the use of the phases 13 2 3 Connection of an external...

Страница 4: ...lter and be controlled using semiconductor devices Always connect the container of the instrument to the earth conductor 1 2 Operating of the instrument Attention the CSQ Visual is not and could not b...

Страница 5: ...strument s inputs and outputs must be the same that powers the inputs and outputs of the PLC We recommend the use of at least one output START signal and three inputs of the PLC GO GOOD and REJECTED I...

Страница 6: ...t of the card Figure 1 Main power terminal block X24 The electronics of the CSQ Visual and the transducers are powered at 24VDC via the X24 three pole terminal block Name Function Terminal 0VDC Negati...

Страница 7: ...y a jobs see 2 PHASE SELECTOR The binary value of these inputs select automatically the phase of job BASKET 1 2 Input for sensor for the detection of normal rejected basket BASKET 2 3 Input for sensor...

Страница 8: ...f the cylinder until the next start The output is intermittent until the reset signal PRESS 2 Enables the press Active after the start if the instrument is ready and deactivated upon reaching the stop...

Страница 9: ...put is internal connected to 0V 10V X12 7 10V potentiometer power 10mA max POT X12 8 Positive analog differential input potentiometer cursor with J4 this imput accept 0 20mA signal Electrical features...

Страница 10: ...J10 Load cell 2mV V supply 10V push only A A OUT A Load cell 2mV V supply 10V push pull B OUT OUT A Load cell 2mV V supply 5V push pull A OUT OUT B Analog input 0 10V OUT B IN A Analog input 0 5V OUT...

Страница 11: ...Q Visual Pin 3 TX interface output signal from the CSQ Visual Pin 5 GND Optional analog outputs X16 Nome Morsetto Descrizione CLK X16 1 Do not connect CLK X16 2 Do not connect DIR X16 3 Do not connect...

Страница 12: ...m the work selected automatically to create an extra work and use a work other than that selected automatically the unlock password in required Automatic selection only works if the instrument START i...

Страница 13: ...after the other hence the need to analyse all the different machining phases The CSQ Visual is able to manage up to four phases for each single process The choice of the phase may take place automatic...

Страница 14: ...nic sensor with a PNP positive logic output 2 4 SETPOINT output The CSQ Visual has an auxiliary output which can be activated when a determined absolute position or a determined force have been reache...

Страница 15: ...the internal cards by a few centimetres Then release the cards from the front panel Figure 4 Pull out all the cards from the container and remove the five terminal block units To fasten the instrumen...

Страница 16: ...card Lastly insert the terminal block units paying attention to the direction Make sure that cables are not squashed on the bottom of the instrument After completing the wiring it is possible to suppl...

Отзывы: