ALFAMATIC CSQ-Visual Скачать руководство пользователя страница 5

 

The  correct  alignment  of  the  encoder  takes  place  using  its  zero  notch  and  the  T.D.C.  withdraw 
cylinder signal. 

1.3  Internal cards 

There are two cards inside the 

CSQ–Visual

frontal

  

(CSQVMB) supports the display, keyboard and main CPU. 

input e output 

(VIO) for the connection of input signals, output signals and transducers. 

We make all the cards  ourselves and they can be altered to suit your specific requirements. 

1.4  Electric wiring 

The following information explains how to install the electric wiring. 

1.4.1 

Information for connection to an external controller (PLC) 

To  connect  the 

CSQ-Visual

  to  a  PLC,  the  latter  must  have  PNP  positive  logic.  The  inputs  and 

outputs  of  the  instrument  are  optoinsulated  from  the  instrument’s  control  electronics.  The  power 
supply of the instrument’s inputs and outputs must be the same that powers the inputs and outputs 
of the PLC. We recommend the use of at least one output (START signal) and three inputs of the 
PLC  (GO,  GOOD  and  REJECTED).  If  necessary,  with  the  press  controlled  directly  by  the 
instrument, it is possible to use a single input to know whether the piece is good (GOOD output) 
and a single output to control the start of the pressing cycle (START input). 
Remember that, in all cases, it is always necessary too connect the T.D.C. input of the 

CSQ-Visual

The T.D.C. signal can be acquired directly by a limit switch activated with the press in the resting 
position.  However,  the  signal  indicating  that  the  press  is  in  the  resting  position  is  almost  always 
used by the PLC. In this case the signal to be given to the instrument may be taken parallel to that 
delivered to the PLC. 

1.4.2 

VIO9 card wiring 

Attention:  this  information  refers  only  to  the  VIO9  card.  Check  that  the  correct  type  of  card  is 
fitted. 

Содержание CSQ-Visual

Страница 1: ...Mar 7 2017 CSQ Visual Version with VIO9 card Installation manual...

Страница 2: ...2...

Страница 3: ...of the instrument 4 1 3 Internal cards 5 1 4 Electric wiring 5 2 Special functions 12 2 1 Configure automatic work selection 12 2 2 Configuring the use of the phases 13 2 3 Connection of an external...

Страница 4: ...lter and be controlled using semiconductor devices Always connect the container of the instrument to the earth conductor 1 2 Operating of the instrument Attention the CSQ Visual is not and could not b...

Страница 5: ...strument s inputs and outputs must be the same that powers the inputs and outputs of the PLC We recommend the use of at least one output START signal and three inputs of the PLC GO GOOD and REJECTED I...

Страница 6: ...t of the card Figure 1 Main power terminal block X24 The electronics of the CSQ Visual and the transducers are powered at 24VDC via the X24 three pole terminal block Name Function Terminal 0VDC Negati...

Страница 7: ...y a jobs see 2 PHASE SELECTOR The binary value of these inputs select automatically the phase of job BASKET 1 2 Input for sensor for the detection of normal rejected basket BASKET 2 3 Input for sensor...

Страница 8: ...f the cylinder until the next start The output is intermittent until the reset signal PRESS 2 Enables the press Active after the start if the instrument is ready and deactivated upon reaching the stop...

Страница 9: ...put is internal connected to 0V 10V X12 7 10V potentiometer power 10mA max POT X12 8 Positive analog differential input potentiometer cursor with J4 this imput accept 0 20mA signal Electrical features...

Страница 10: ...J10 Load cell 2mV V supply 10V push only A A OUT A Load cell 2mV V supply 10V push pull B OUT OUT A Load cell 2mV V supply 5V push pull A OUT OUT B Analog input 0 10V OUT B IN A Analog input 0 5V OUT...

Страница 11: ...Q Visual Pin 3 TX interface output signal from the CSQ Visual Pin 5 GND Optional analog outputs X16 Nome Morsetto Descrizione CLK X16 1 Do not connect CLK X16 2 Do not connect DIR X16 3 Do not connect...

Страница 12: ...m the work selected automatically to create an extra work and use a work other than that selected automatically the unlock password in required Automatic selection only works if the instrument START i...

Страница 13: ...after the other hence the need to analyse all the different machining phases The CSQ Visual is able to manage up to four phases for each single process The choice of the phase may take place automatic...

Страница 14: ...nic sensor with a PNP positive logic output 2 4 SETPOINT output The CSQ Visual has an auxiliary output which can be activated when a determined absolute position or a determined force have been reache...

Страница 15: ...the internal cards by a few centimetres Then release the cards from the front panel Figure 4 Pull out all the cards from the container and remove the five terminal block units To fasten the instrumen...

Страница 16: ...card Lastly insert the terminal block units paying attention to the direction Make sure that cables are not squashed on the bottom of the instrument After completing the wiring it is possible to suppl...

Отзывы: