ALFAMATIC CSQ-Visual Скачать руководство пользователя страница 12

12 

 

2  Special functions 

2.1  Configure automatic work selection 

The 

CSQ-Visual

 supports the automatic selection of work using the combination of the inputs or a 

command  sent  to  the  serial  port.    This  selection  can  be  useful  for  automatically  recognising  the 
piece or the tool fitted.  
To  enable  the  automatic  selection  of  work  it  is  necessary  to  give  the  instrument  the  maximum 
number of selectable works and the way in which they are selected. 
To  do  this,  select  the 

TOOLS  >  ADVANCED  OPTIONS  >  MACHINE  TYPE  >  WORKS  PHASES 

CHANNELS

 menu and  change the 

Number  of  selectable  works

 value; then indicate the selection 

mode, changing the 

Automatic selection code

After changing the configuration, the instrument will create the selectable works, initially empty; to 
make an empty work suitable for use, use the 

WORKS MANAGEMENT > CHANGE WORK

 command 

and press enter on the work required. Now change the name of the work. The 

CREATE NEW WORK

 

item  in  the 

WORKS  MANAGEMENT

  menu  enables  the  creation  of  extra  works  which  can  be  used 

separately from the work selected automatically; to create an extra work and use a work other than 
that selected automatically the unlock password in required. 
Automatic selection only works if the instrument START input is not active.  

2.1.1  Selection through inputs 

The  work  number  is  obtained  from  the  binary  combination  of  the  inputs.  The  binary  code  of  the 
first work is zero, i.e.: no input active.  The maximum number of selectable works, if enough inputs 
are available, is 64 (with binary codes from 0 to 63). 
The wiring is connected to a terminal block inside the instrument marked X3.  
The highest inputs must be used for selection. 

Example:

 assuming the use of the CSQVIO card, which has 8 inputs, if it is necessary to select a 

maximum  of  4  works,  inputs  7  and  8  will  be  used:  input  8  will  be  the least  significant  bit,  while 
input 7 will be the most significant. 

2.1.1.1  Connection of sensors for work selection 

It is possible to use positive logic sensors (PNP) or clean contacts for connection to positive. 
For example, if it is necessary to connect 4 sensors to the instrument (selection from 9 to 16 works) 
which has 8 inputs, inputs 5, 6, 7 and 8 must be used. Input 8 will be the least significant bit, while 
input 5 will be the most significant. 

Содержание CSQ-Visual

Страница 1: ...Mar 7 2017 CSQ Visual Version with VIO9 card Installation manual...

Страница 2: ...2...

Страница 3: ...of the instrument 4 1 3 Internal cards 5 1 4 Electric wiring 5 2 Special functions 12 2 1 Configure automatic work selection 12 2 2 Configuring the use of the phases 13 2 3 Connection of an external...

Страница 4: ...lter and be controlled using semiconductor devices Always connect the container of the instrument to the earth conductor 1 2 Operating of the instrument Attention the CSQ Visual is not and could not b...

Страница 5: ...strument s inputs and outputs must be the same that powers the inputs and outputs of the PLC We recommend the use of at least one output START signal and three inputs of the PLC GO GOOD and REJECTED I...

Страница 6: ...t of the card Figure 1 Main power terminal block X24 The electronics of the CSQ Visual and the transducers are powered at 24VDC via the X24 three pole terminal block Name Function Terminal 0VDC Negati...

Страница 7: ...y a jobs see 2 PHASE SELECTOR The binary value of these inputs select automatically the phase of job BASKET 1 2 Input for sensor for the detection of normal rejected basket BASKET 2 3 Input for sensor...

Страница 8: ...f the cylinder until the next start The output is intermittent until the reset signal PRESS 2 Enables the press Active after the start if the instrument is ready and deactivated upon reaching the stop...

Страница 9: ...put is internal connected to 0V 10V X12 7 10V potentiometer power 10mA max POT X12 8 Positive analog differential input potentiometer cursor with J4 this imput accept 0 20mA signal Electrical features...

Страница 10: ...J10 Load cell 2mV V supply 10V push only A A OUT A Load cell 2mV V supply 10V push pull B OUT OUT A Load cell 2mV V supply 5V push pull A OUT OUT B Analog input 0 10V OUT B IN A Analog input 0 5V OUT...

Страница 11: ...Q Visual Pin 3 TX interface output signal from the CSQ Visual Pin 5 GND Optional analog outputs X16 Nome Morsetto Descrizione CLK X16 1 Do not connect CLK X16 2 Do not connect DIR X16 3 Do not connect...

Страница 12: ...m the work selected automatically to create an extra work and use a work other than that selected automatically the unlock password in required Automatic selection only works if the instrument START i...

Страница 13: ...after the other hence the need to analyse all the different machining phases The CSQ Visual is able to manage up to four phases for each single process The choice of the phase may take place automatic...

Страница 14: ...nic sensor with a PNP positive logic output 2 4 SETPOINT output The CSQ Visual has an auxiliary output which can be activated when a determined absolute position or a determined force have been reache...

Страница 15: ...the internal cards by a few centimetres Then release the cards from the front panel Figure 4 Pull out all the cards from the container and remove the five terminal block units To fasten the instrumen...

Страница 16: ...card Lastly insert the terminal block units paying attention to the direction Make sure that cables are not squashed on the bottom of the instrument After completing the wiring it is possible to suppl...