34/37
ALFA IN a.s ©
www.alfain.eu
17. TORCH CONNECTION SCHEMA
18. CNC REMOTE CONTROL CONNECTION
DIVIDER
PIN #
DIRECTION
1
Current setting Input I+
8
Trigger
9
Trigger
6
Divider output arc voltage (+)
7
Divider output arc voltage (-)
Current setting Input I-
13
Signal OK move cutting arc is ON
14
Signal OK move cutting arc is ON
Machines with a CNC interface are equipped with the possibility of remote
current setting. The setting is performed using current from an external source.
The output current of the machine can be controlled in the range of 20A up to
the value set by the encoder, ie if we set the potentiometer with eg 60A, we will
be able to control the current by an external signal in the range of 20-60A.
Remote current setting control signal 3 - 25mA (1 - 5V)
PIN #.
DIRECTION
1
/
2
/
3
/
4
/
5
Pilot arc
6
Pilot arc
7
/
8
Safety
9
Safety