11/37
ALFA IN a.s ©
www.alfain.eu
possible to the cutter. This is especially important for older distribution
systems made of conventional steel pipes, where the inner walls can be
considerably corroded. It is necessary to use a filter with a sludge trap in
systems with long distributions that pass through a cold environment, where
compressed air can cool to the dew point and thus condense water droplets.
AIR FILTER AND WATER SEPARATOR FOR SVAROG PLASMA
In order to achieve high cutting quality and to avoid serious faults on the torch,
it is strongly recommended that a separator or at least a filter be always included
in the inlet (
Fig. 1).
Fig. 1 Air Filter and Separators
Pos.
Code
Description
S1
5304
Filter - set AT 1000 k SVAROG PLASMA
S2
5302
Air filter AT 1000
S3
7704
Water separator including fittings
S4
6079
Condensate drain
Note
Max. operating pressure of the AT 1000 filter is 8.5 bar.