7/19
ALFA IN a.s.
©
www.alfain.eu
Welding current (DC=100%) I
2
A
85
120
Welding current (DC=60%) I
2
A
105
140
Welding current (DC=x%) I
2
A
10%=200
25%=200
Protection
IP23S
Standards
EN 60974-1, EN 60974-10 cl. A
Dimensions (w x l x h)
mm
160 x 460 x 280
Weight
kg
7,0
Note on SW limitations of loaders:
SW limitation is active at the following load:
PERUN 160 T HF: I
2
= 150 - 160 A
PERUN 200 T HF: I
2
= 190 - 200 A
The running time of the machine is limited to 5 minutes. Subsequently the LED
of overheating the machine
V18
lights up and the error message
„E 09
– SW
protection of overheating“
appears on the display
V14
and the output current
is blocked for 5 minutes. After this time, the LED of overheating the machine
V18
goes out, the error message
E 09
disappears from the display
V14
and the
operation of the machine is unlocked.
5. EQUIPMENT
PART OF THE DELIVERY
Item No.
Description
Picture
5.0310
PERUN 160 T HF
5.0315
PERUN 200 T HF