12/19
ALFA IN a.s.
©
www.alfain.eu
7. GETTING STARTED
Getting started must be consistent with technical data and conditions of use.
GETTING STARTED MMA – COATED ELECTRODE
Figure 3. MMA welding set up
1. Insert the mains plug into a suitable 1x230 V mains socket.
2. Connect the welding cables to the panel quick connectors (+)
A3
and (-)
A1
according the instruction on the electrodes packing.
3. Switch the machine on by means of the ON/OFF switch
A6.
4. By means of the welding method switch
V7
select MMA method. The
corresponding LED
V6
will light up.
5. By means of the encoder
V22
set the welding current. The values will be
showed on the display
V14
.
6. It is possible to change the settings of the
HOT START
(increase of current
during arc ignition time),
ARC FORCE
(an automatic increase of the welding
current in case the electrode touches the welding piece) by means of the
encoder
V22
.
NOTE
Prevent touching the electrode any metal material for in this mode
the quick connectors
A3
and
A1
are under current.
7. Insert the coated electrode into the electrode holder, connect the clamps of
the ground cable to the welding piece and you may start welding.