20. Remove O-ring (38) from lower plug stem (75).
21. Remove plug (15).
22. Slide lock (44) along piston rod
(29).
23. Remove two clamps (43).
24. Pull upper plug (55), and upper
sealing element (48) out.
25. Remove spindle liner (42).
26. Remove lock (44).
44
42
48
55
29
44
15
43
38
75
*